RELAYS
Except for the grid heater and starter relay, all re-
lays are fitted on the relay panel that is located left
of the fuse panel. The relay panel contains 15
smaller relays, plus the main power relay. The 15
smaller relays are identical and can be swapped to
check functionality. The relay panel can also con-
tain a flasher unit. See Figure 5.
Figure 5. Relay Panel
Table 8. Legend for Figure 5
Item
Description
Con-
nector
Tier
III
Tier
IV
1
Flood Lights
CPS62
[55,I]
[64,I]
2
Main Lights
CPS62
[56,I]
[64,I]
3
Start Inhibit
CPS13 [29,C] [29,C]
4
Neutral
CPS13 [29,B] [29,B]
5
Hydraulic Con-
troller
CPS36 [27,H] [26,H]
6
Reverse Lights/
Alarm
CPS36
[62,I]
[71,J]
7
Main Power
CPS16 [27,E] [26,E]
8
AC Fan 3
CPS115 [159,F] [168,F]
9
Ignition
CPS15 [27,G] [26,G]
10
AC Fan 2
CPS115 [159,E] [168,E]
11
AC Fan 1
CPS115 [159,E] [168,E]
12
Flasher Unit
CPS76 [72,B] [81,B]
13
Start Enable
CPS120
---
[30,E]
14
Twist Lock/
Unlock
CPS120 [125,E] [134,E]
15
12 Volt Relay
CPS108 [145,F] [154,F]
16
CH Override
CPS108 [87,B] [96,B]
17
Horn
CPS84 [147,C] [155,C]
18
Seat Switch
CPS84 [116,I] [125,I]
Electrical Schematic and System Description
2200 SRM 1592
12