11
4.2 Instructions for batteries wiring.
This instruction is for 12V Lead-acid batteries. Make sure all the batteries are same
specification, same voltage level.
Note: Flip OFF the battery breaker before wiring.
BE CAUTIOUS! Wrong wiring may cause damage, battery short circuit may cause fire.
4.2.1 Remove the battery fixed brackets before load the batteries. The battery terminals side
to the SPS front.
4.2.2 Put on the battery terminal insulated caps with the cables before wiring. 4 12V-batteries
on same level are wired in series which will create 48V battery group. 2 of 48V-battery group
are wired in parallel. Refer to above picture for battery wiring.
4.2.3 Well tighten the screws. Loosened screws will cause heating issue.
4.3 Solar Wiring Instructions
4.3.1 All the solar panels in same array are supposed to be same specification. Check the
open circuit voltage on the solar panels, calculate quantity for each string. The string voltage
range is (VoC=60V-150V). All the strings voltage differences less than 5%.