background image

3501 Actuator

INSTALLATION REFERENCE MANUAL

2

  www.hysecurity.com • 800-321-9947 

MX4754 Rev. B  ©2019

TABLE OF CONTENTS

LIST OF INSTRUCTIONS

INSTRUCTION 1:

  DETERMINE LOCATION OF MOUNTING POST  ..................... 5

INSTRUCTION 2:  

DETERMINE HEIGHT OF MOUNTING POST ........................... 6

INSTRUCTION 3:  

WELD MOUNTING BRACKET TO POST ................................... 7

INSTRUCTION 4:  

MOUNT CHASSIS TO POST ...................................................... 8

INSTRUCTION 5:  

MOUNT PRIMARY ARM COLLAR TO DRIVE SHAFT................. 9

INSTRUCTION 6:  

ATTACH PRIMARY ARM TO ARM COLLAR ............................. 10

INSTRUCTION 7:  

ASSEMBLE ARM ASSEMBLY .....................................................11

INSTRUCTION 8:  

AFFIX GATE BRACKET TO ACTUATOR ARM ..........................13

INSTRUCTION 9:  

INSTALL GATE BRACKET TO GATE SUPPORT ........................15

INSTRUCTION 10:  

WIRE ACTUATOR CABLE TO CHASSIS TERMINAL STRIP ....16

INSTRUCTION 11:  

RUN ACTUATOR CABLE(S) TO CONTROL BOX ...................17

INSTRUCTION 12A:  

WIRE ACTUATOR CABLE TO CONTROL BOARD (LEFT) ...18

INSTRUCTION 12B:  

WIRE ACTUATOR CABLE TO CONTROL BOARD (RIGHT) .19

INSTRUCTION 12C:  

WIRE ACTUATOR CABLE TO CONTROL BOARD (DUAL) .. 20

INSTRUCTION 13:  

INSTALL CONTROL BOX AND APPLY POWER ................... 20

INSTRUCTION 14:  

SET OPEN AND CLOSE LIMIT COLLARS ................................. 21

INSTRUCTION 15:  

WELD OR BOLT GATE BRACKET TO GATE ......................... 22

INSTRUCTION 16:  

MANUALLY OPENING THE GATE ....................................... 23

SECTION 1: 3501 ACTUATOR OVERVIEW ..........................................................3

SECTION 2: INSTALLATION SAFETY  ..................................................................4

SECTION 3: TOOLS NEEDED FOR INSTALLATION ............................................4

SECTION 4: 3501 ACTUATOR MECHANICAL INSTALLATION ...........................5

SECTION 5: ACTUATOR WIRING

 CONNECTIONS ...........................................16

    5.1  CHASSIS WIRING .........................................................................................16

    5.2  CONTROL BOARD WIRING...........................................................................18

SECTION 6: PART DRAWINGS ..........................................................................24

SECTION 7: WARRANTY .................................................................................. 26

Содержание Nice 3501

Страница 1: ...strial Anti Ram Parking 800 321 9947 253 867 3700 www hysecurity com 3501 Swing CHBOX35 ACTUATOR MOTOR CHASSIS ABOX35 ARTICULATING ACTUATOR Vehicular swing gate articulating actuator motor MX4754 REV...

Страница 2: ...WIRE ACTUATOR CABLE TO CHASSIS TERMINAL STRIP 16 INSTRUCTION 11 RUN ACTUATOR CABLE S TO CONTROL BOX 17 INSTRUCTION 12A WIRE ACTUATOR CABLE TO CONTROL BOARD LEFT 18 INSTRUCTION 12B WIRE ACTUATOR CABLE...

Страница 3: ...eaf GATE WEIGHT MAX Up to 1000 lbs 453 kg OPEN CLOSE TIME TO 90 12 20 seconds adjustable TEMPERATURE RATING 4 to 122 F 20 to 50 C OPERATING VOLTAGE 12VDC INPUT VOLTAGE 10 32VDC ACTUATOR DIMENSIONS WxH...

Страница 4: ...is the responsibility of the property owner to ensure the installer is qualified to carry out the installation in a safe and professional manner Consult local government agencies for up to date rules...

Страница 5: ...nces of B are from the center of gate hinge to the center of the mounting post Longer gates should operate at slower speeds 3 Refer to TABLE 1 1 for optimum dimensions SECTION 4 35 1 ACTUATOR MECHANIC...

Страница 6: ...nting post should be square to the gate in the closed position and level for proper operation Conduit should be considered at this time for cable routing from the control box to the chassis assembly D...

Страница 7: ...OVER REMOVE BOTH END SCREWS x2 1 To remove 3501 cover loosen middle screws x2 remove end screws x2 and lift off cover 1 Remove the mounting bracket from the CHBOX35 chassis bottom by removing the four...

Страница 8: ...lts and lock washers removed in the previous instruction IMAGE 4 1 MOUNTING CHASSIS TO MOUNTING BRACKET IMAGE 4 2 PROPER ORIENTATION OF CHASSIS TO GATE Chassis should be mounted to plate so that the s...

Страница 9: ...ssible IMAGE 5 2 Use 5 32 hex key to tighten set screw Insert 1 2 13x3 hex bolt into collar and affix with 1 2 hex nut IMAGE 5 2 using 1 2 wrench 3 Use retaining ring pliers to insert the retaining ri...

Страница 10: ...ACH PRIMARY ARM TO ARM COLLAR IMAGE 6 1 INSTALL PRIMARY ARM TO COLLAR OF THE MAIN DRIVE SHAFT BOTTOM VIEW IMAGE 6 2 PRIMARY ARM INSTALLED TO COLLAR OF THE MAIN DRIVE SHAFT BOTTOM VIEW PRIMARY ARM ARM...

Страница 11: ...SECONDARY ARM ADJUSTABLE ALUMINUM ARM INSERT SET SCREW ASSEMBLE ARM ASSEMBLY BOLT NUT STEEL WASHER STEEL WASHER BOLT WASHER NUT WASHER IMAGE 7 1 ARM ASSEMBLY EXPLODED VIEW 1 2 13x2 1 4 HEX BOLT 1 2 B...

Страница 12: ...rogrammed this aluminum arm can be adjusted to fine tune the closed gate position 1 Attach the secondary arm to the primary arm using a 1 2 13x2 1 4 hex bolt brass washers and lock nut see IMAGE 7 1 T...

Страница 13: ...ost importance then the bracket may be connected to the actuator arm using the 1 2 x 3 bolt washers and lock nut IMAGE 8 1 However to enable quick manual opening of the gate in case of power failure i...

Страница 14: ...y com 800 321 9947 MX4754 Rev B 2019 IMAGE 8 2 GATE BRACKET TO ACTUATOR ARM USING HITCH PIN AND R CLIP HITCH PIN R CLIP INSERT INTO HITCH PIN HOLE HOLE FOR R CLIP 3 AFFIX GATE BRACKET TO ACTUATOR ARM...

Страница 15: ...shown below 3 Tack weld or clamp the gate attach bracket to the gate NOTE Permanent welds or bolt attachment should be completed once limits are set IMAGE 9 1 POSITIONING GATE BRACKET ON GATE STRUCTUR...

Страница 16: ...UATOR TO CHASSIS TERMINAL STRIP Located inside the chassis assembly next to the limit switch assembly is a white terminal strip Wire the harness cable to the terminal strip as shown below 5 1 CHASSIS...

Страница 17: ...e installation 1 Dig a trench across the driveway deep enough to accommodate the longer harness cable from the actuator furthest from the control box 2 Run the cable through an appropriate conduit and...

Страница 18: ...e actuator cable to the control board as shown below IMAGE 12A 1 LEFT OPENING GATE ACTUATOR TO CONTROL BOARD WIRING NOTE If a gate moves in opposite direction from what is expected reverse the motor p...

Страница 19: ...shown below NOTE If a gate moves in opposite direction from what is expected reverse the motor power lead wiring red black wires for that motor IMAGE 12B 1 RIGHT OPENING GATE ACTUATOR TO CONTROL BOARD...

Страница 20: ...INSTRUCTION 14 in this manual IMAGE 12C 1 DUAL OPENING GATE ACTUATOR TO CONTROL BOARD WIRING NOTE If a gate moves in opposite direction from what is expected reverse the motor power lead wiring red b...

Страница 21: ...ing the OPEN button on the front of the Control Board press and hold the button down until the gate reaches the desired open position 3 Rotate the OPEN Limit collar by hand until the appropriate Limit...

Страница 22: ...rill two holes to match bracket and affix with two 3 8 16x2 1 2 hex bolts and 3 8 nuts included in the kit IMAGE 15 1 IMAGE 15 1 GATE BRACKET AND HARDWARE GATE BRACKET 3 8 16 x2 1 2 HEX BOLT x2 3 8 NU...

Страница 23: ...per IMAGE 16 1 flip toward motor 2 Pull or push the gate at the actuator arm elbow or at edge of gate 3 To put gate operator back into service flip motor switch back to ON per IMAGE 16 1 flip toward...

Страница 24: ...0 all Bracket Gate Attach Kit 10021290 all Bracket Post Mount 10038315 all Chassis Assembly 3501 CHBOX35 all Collar and Magnet 10021490 all Cover Plastic MX4774 all Gearmotor 73090005 all Limit Block...

Страница 25: ...NG 3 1 1 03 03 ITEM NO PART NUMBER DESCRIPTION QTY 1 1125 35 KIT HW F 3500 W O GATE BRKT 1 2 3500AAA ARM ADJUST ALUM F 3500 1 3 10025215 BRKT GATE 1 4 1 4 10031390 ARM SECONDARY F 3500 1 5 10045790 IN...

Страница 26: ...on level The preceding warranties do not extend to accessories when those items carry the name plate of a manufacturer other than HySecurity or Nice and they are not a part of the base model HySecurit...

Страница 27: ...3501 Actuator INSTALLATION REFERENCE MANUAL 27 MX4754 Rev B 2019 www hysecurity com 800 321 9947 This page intentionally blank...

Страница 28: ...ased for publication 10 17 2019 Curtis Harvey Rev B Added drive shaft retaining ring and x2 washers on articulating arm per Russ 11 05 2019 INSTALLATION INFORMATION AND SIGN OFFS Installation Acceptan...

Отзывы: