S
mart
t
OucH
: t
He
S
OLutiOn
, mim-62 (m
uLti
-
input
m
OduLe
)
1. Turn OFF AC power.
2. Input channels 1 and 2 must be used and are always assigned to OUTPUT A.
3.
All other input channels may be configured to either A or B.
NOTE:
If different sensor types are connected to the same output, then program the Controller SENSOR type
for EDGE options.
4. Turn ON power.
5.
Access the Installer Menu. Configure SENSOR setting according to the types of sensors wired to the
Smart Touch Controller.
24V A
C Acce
ssory
po
wer
+ 24
V D
C
COMM
ON
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
1
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
SENSOR
COM
DO NOT USE
SENSOR 2
DO NOT USE
SENSOR 3
DO NOT USE
CHARGER
AC LOSS
LOCK INTERLOCK
EMERG CLOSE
FIRE DEPT OPEN
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
Smart Touch Controller
LIMIT
DUAL GATE
RADIO OPTIONS
DRIVE
POWER
RS485
MO
TOR
USER 1
USER 2
USER 3
VEHI
CLE DETE
CT
OR
VEHICLE DETE
CT
OR
VEHICLE DETE
CT
OR
ST
OP
/BUZZER
FREE
EXIT
INSIDE
OB
STR
OUT
SIDE
OB
STR
SHADO
W
RE
SET
WIE
GAND
Hy
Security
COM
NO
MX000585
VERSION
S/N
RS232
DISPLA
Y
VEHI
CLE DETE
CT
OR
COM
COM
A
B
RPM
COM
OPEN
S 1
+24V
+24V
STATUS
LED
Connect either output
(P/NC wire) to SENSOR 1,
2, or 3.
Power Supply Board
CAUTION
All external entrapment protection sensors must be NC sensor
outputs and wired to the SENSOR COM terminal for monitoring
and powering purposes. The sensor becomes actively powered
when the gate operator's motor runs.
© 2018
Wiring HySecurity Sensors: Smart Touch
MX3636-01 Rev. D
117
Содержание HSG80F
Страница 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Страница 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Страница 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Страница 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Страница 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...