HyQuest Solutions TB71 Скачать руководство пользователя страница 5

§

Read the user manual including all operating instructions prior to installing, connecting and powering up the HyQuest
Solutions TB71. The manual provides information on how to operate the product. The manual is intended to be used
by qualified personnel,  i.e.  personnel  that  have  been  adequately  trained,  are  sufficiently  familiar  with  installation,
mounting, wiring, powering up and operation of the product.

§

Keep the user manual on hand for later reference!

§

If  you  encounter  problems  understanding  the  information  in  the  manual  (or  part  thereof),  please  consult  the
manufacturer or its appointed reseller for further support.

§

HyQuest Solutions TB71 is intended to be used in hydrometeorological or environmental monitoring applications. 

§

Before starting to work, you have to check the functioning and integrity of the system.

§

Check for visible defects on the TB71, this may or may not include any or all of the following mounting facilities,
connectors  and  connections,  mechanical  parts,  internal  or  external  communication  devices,  power  supplies  or
power supply lines, etc.

§

If defects are found that jeopardize the operational safety, work must be stopped. This is true for  defects  found
before starting to work as well as for defects found while working.

§

Do not use the HyQuest Solutions TB71 in areas where there is a danger of explosion.

§

The present  user  manual  specifies  environmental/climatic  operating  conditions  as  well  as  mechanical  and  electrical
conditions.  Installation,  wiring,  powering  up  and  operating  the  HyQuest  Solutions  TB71  must  strictly  comply  with
these specifications.

§

Perform maintenance only when tools or machinery are not in operation.

§

If guards are removed to perform maintenance, replace them immediately after servicing.

§

Never  make  any  electrical  or  mechanical  diagnostics,  inspections  or  repairs  under  any  circumstances.  Return  the
sensor to the manufacturer’s named repair centre. You can find information on how to return items for repair in the
relevant section of the HyQuest Solutions web site.

§

  Disposal  instructions:  After  taking  the  HyQuest  Solutions  TB71  out  of  service,  it  must  be  disposed  of  in

compliance with local waste and environmental regulations. The HyQuest Solutions TB71 is never  to  be  disposed  in
household waste!

§

 Inputs and outputs of the device are protected against electric discharges  and  surges  (so-called  ESD).  Do  not

touch any part of the electronic components! If you need to touch any part, please discharge yourself, i.e. by touching
grounded metal parts.

III        Safety Instructions

© 2022 HyQuest Solutions

5

Содержание TB71

Страница 1: ...TB71 User Manual ...

Страница 2: ...Rain Gauge 7 2 2 Site Selection and Setup 7 2 3 Quick Instruction 7 Part III Configuration 12 3 1 Calibration 12 Part IV Operation 13 4 1 Test Operation 13 4 2 Electrical 13 Part V Maintenance 14 Part VI Repair 16 6 1 TB7 Part List 16 Part VII Technical Data 21 Part VIII Obligations of the Operator and Disposal 22 8 1 Obligations of the Operator 22 8 2 Dismantling Disposal 22 ...

Страница 3: ...ormation provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred This manual does not include all of the details of design production or variation of the equipment nor does it cover every possible situation which may arise during installation operation or maintenance HyQuest Solutions shall not be liable for any incidental indire...

Страница 4: ... 2022 HyQuest Solutions 4 II Scope of Delivery TB7 Rain Gauge TB311 5 5 metre connecting lead Bird Spikes with Quick Instruction Allen Key 2022 HyQuest Solutions 4 ...

Страница 5: ... found before starting to work as well as for defects found while working Do not use the HyQuest Solutions TB71 in areas where there is a danger of explosion The present user manual specifies environmental climatic operating conditions as well as mechanical and electrical conditions Installation wiring powering up and operating the HyQuest Solutions TB71 must strictly comply with these specificati...

Страница 6: ...ement practitioners in the field The present User Manual will help you understand install and deploy the device If however you feel that a particular information is missing incomplete or confusing please do not hesitate to contact us for further support HyQuest Solutions TB7 is a new generation high quality tipping bucket rain gauge for measuring rainfall and precipitation in remote and unattended...

Страница 7: ...sentative of the actual rain falling on a given area Some of the more important factors which influence the representativeness of a gauge are as follows Site the gauge on level ground where possible Avoid sloping sites Site should have adequate protection from strong winds Site should be free of large obstructions such as buildings and trees Provide suitable ground surface to avoid splashing into ...

Страница 8: ... 2022 HyQuest Solutions 8 Installation Base Instruction ...

Страница 9: ... 2022 HyQuest Solutions 9 Installation Floor Mount ...

Страница 10: ... 2022 HyQuest Solutions 10 Installation Pole Mount Roof Mount The Rain Gauge can also be mounted on a pitched roof with maximum angle of 15 degrees ...

Страница 11: ... 2022 HyQuest Solutions 11 Installation ...

Страница 12: ...d buretted to the practical volume applicable to the resolution of the gauge i e 0 2mm or 0 5mm or 0 01 The buretting is carried out with NATA calibrated and certified equipment Initial Calibration The initial production run of 50 rain gauges are all buretted as described in Item i above and calibrated on our TB340A Laboratory calibrator over a range of intensities 50mm hr to 500mm hr Ongoing Cali...

Страница 13: ...g freely Replace and secure the enclosure 4 2 Electrical Dual reed switches are provided for several reasons Two isolated switches permit the control of two separate circuits e g a local counter and a telemetry circuit Parallel connection of both switches increases the current carrying capacity of the contact system if required Parallel switch operation confers a degree of redundancy in locations ...

Страница 14: ... checked regularly for cleanliness Catch filter Straight through Nozzle refer diagram 5 Interior of bucket Top surface of adjusting screws Enclosure locking screws lightly lubricate after cleaning All insect screens Dismantle Details a Push filter in and pull straight through Nozzle out b Clean filter c Clean straight through nozzle ...

Страница 15: ... 2022 HyQuest Solutions 15 Maintenance Assembly Details Assemble filter to straight through Nozzle body Push assembly into funnel ...

Страница 16: ...turn shipment 2 Please provide as much information and or clear instructions within the return paperwork This will assist our test engineers with their diagnosis 3 Please do not ship the goods prior to obtaining the reference number HyQuest Solutions will not reject any equipment that arrives without reference number however it may take us longer to process Custom requirements for items sent to Hy...

Страница 17: ...0 01inch bucket type UV stabilised Teflon impregnated injection moulded TB7 0 5 Tipping Bucket Rain Gauge bucket capacity 0 5mm bucket type UV stabilised Teflon impregnated injection moulded TB7 Base Part List REFERENCE PART_ID DESCRIPTION QTY_PER 1 TB701 01 BASE INJECTION MOULDED 1 2 TB701 03 BRASS INSERT 2 3 SC008 29 M5x0 8 SS304 HEX NUT 3 4 SC045 21 SOC HD CAPSCREW M5x0 8x12 SS304 3 5 TB301 05 ...

Страница 18: ...HD PHILLIPS STAINLESS STEEL 1 9 TB307 MODEL TB3 RAIN GAUGE 24V REED SWITCH ASSEMBLY 0 5 10 SC023 09 BULL S EYE LEVEL 1 11 SC100 09 SERIAL PLATE 1 12 SC100 06 CALIBRATED LABEL 1 13 SC040 58 SPFM10 10MM FINNED SNAP IN PLUG BLACK 1 14 TB312 ADJUSTING SCREW ASSEMBLY 2 15 SC022 116 6GA x 1 2 SELF TAPPING SCREW 304 PAN HD PHILLIPS STAINLESS STEEL 2 TB7 Bucket Part List ...

Страница 19: ... 2022 HyQuest Solutions 19 Repair Filter Nozzle Part List Enclosure Part List Part no Description Quantity TB777 01 Funnel 1 ...

Страница 20: ... 2022 HyQuest Solutions 20 Repair Part no Description Quantity TB777 02 Enclosure 1 TB418 06 Vent 1 TB408 05 Mesh 1 TB777 04 Bird Guard Spike 18 6 Spares TB777 breakdown assembly ...

Страница 21: ...5 Flow rate 200 500 mm hr NA NA better than 8 Alternatively Individual accuracy 2 at any set intensity specified by the user calibration required Please note Additional costs for individually calibrated units Enclosure and Base UV resistant ASA Pivots Ground sapphire pivots Bucket Teflon impregnated injection moulded Dimensions Height 310 mm Catch 200 mm diameter Mass 2 1 kg ...

Страница 22: ...ections must be observed 8 2 Dismantling Disposal When disposing of the units and their accessories the applicable local regulations regarding environment disposal and occupational safety must be observed Before dismantling Electrical Devices Switch off the units Disconnect electrical appliances from the power supply regardless of whether the appliances are connected to the mains or to another pow...

Страница 23: ...are committed to supporting efforts to avoid and recycle waste Please consider Avoidance before recycling Recycling before disposal This symbol indicates that the scrapping of the unit must be carried out in accordance with Directive 2012 19 EU Please observe the local implementation of the directive and any accompanying or supplementary laws and regulations ...

Страница 24: ...RS Group HyQuest Solutions KISTERS LATAM HyQuest Solutions NZ Ltd HyQuest Solutions Pty Ltd HyQuest Solutions KISTERS AG 1 561 459 4876 sales hsa kisters net 57 350 575 4079 sales latam hyquestsolutions com 64 7 857 0810 sales hyquestsolutions co nz 612 9601 2022 sales hyquestsolutions com au 49 2408 9385 0 info hyquestsolutions eu ...

Страница 25: ...www hyquestsolutions com 2022 HyQuest Solutions 21 04 2022 ...

Отзывы: