Configuration
.
First Measurement at:
This is the time that the first poll will happen (relative to iRIS local time). Allowing the polling
interval to be offset. If this setting and Measurement Interval are set to 00:00:00 then the
automatic poll regime will be employed.
Measurement
Interval:
The interval at which the device will be polled. Actual poll time can be offset by using a non-
zero First Measurement at setting. If this setting and Measurement Interval are set to 00:00:00
then the automatic poll regime will be employed.
Custom Command:
This is an optional command that can be issued on a separate schedule to the poll for
measurements schedule. The command can be any SDI-12 command, without the address or
closing exclamation mark (!), these are automatically added by the iRIS. Example of use of this
function are, to perform a wipe of the sensor lens or reset a running total. If this command is
blank then the associated schedule will not have an effect.
First Command at:
This is the time that the first custom command will be issued (relative to iRIS local time).
Allowing the custom command issuing interval to be offset. If this setting and Command
Interval are set to 00:00:00 then the custom commands will not be issued.
Command Interval:
The interval at which the custom command will be issued. Actual command issue time can be
offset by using a non-zero First Measurement at setting. If this setting is set to 00:00:00 and
the First Command at setting is not 00:00:00, the custom command will be issued once at the
time defined by the First Measurement at setting.
3.4.5.2
Adding SDI-12 Devices via Address Scan
An SDI-12 device can be detected and setup automatically by using the Address Scan feature of iLink. The device(s) needs
to be attached to the iRIS and have each have a unique address.
A device is initiated by click on the [
START ADDRESS SCAN
] button in the
SDI-12 DEVICE
branch of the configuration tree.
The scan will start immediately and scans the address range 0-9, a-z, A-Z. To speed up the process, click the [
STOP SCAN
]
button when the
TOTAL DEVICES FOUND
is equal to the amount of device attached (already configured or not).