HyQuest Solutions IoTa LTE-M Скачать руководство пользователя страница 29

© 2022 HyQuest Solutions

29

Operation

4.4

Connecting an Antenna

IoTa is equipped with an SMA connector compatible with most LoRa and LTE-M antennas.

The SMA connector (Sub-Miniature Version A) is a radio-frequency coaxial connector with a screwing coupling feature. 

§

Female connector on the IoTa housing: The female connector has a threaded barrel.

§

Male  connector  on  the  antenna  or  on  the  antenna  cable:  male  SMA  connectors  have  a  hex  nut  that  fits  securely
around the female barrel for a tight coupling.

In most applications, an omnidirectional antenna will serve you best.

Choice of Antenna: In most applications, an omnidirectional antenna will serve you best. LoRa and LTE-M do not operate
in the same frequency bands. Use an antenna that is tuned to the appropriate frequency range. Depending on location
and  network  coverage,  an  amplifying  antenna  may  be  preferred.  Caution:  check  with  national  regulations  for  the
maximum amplification allowed for the transmission. This may differ between LoRa and LTE-M.

IoTa  SensorNode  LoRa

:  LoRaWAN  operates  in  ISM  (Industrial,  Scientific  and  Medical) band  of  the  radio  spectrum.

Subsequently, the permitted power levels are very low, typically only +14 dBm in Europe. This means that you will get
better  results  from  using  an  antenna  that  is  tuned  to  operate  in  the  ISM  spectrum.  In  Europe  the  LoRaWAN  profile
operates in several channels close to 868 MHz.

IoTa SensorNode LoRa

: LTE-M is a sub-band of the 4G or 5G. Usually, any antenna tuned to the frequency range of LTE

will do. 

4.5

Data Transmission

This chapter contains the following subsections:

§

LoRa

§

LTE-M

4.5.1

LoRa

Network Coverage: Check network coverage for LoRa/LoRaWAN at the monitoring site.

The maximum number of values transmitted per message is 8.

These 8 values can be obtained from a single multi-parameter SDI-12 sensor. They may also be the sum of up to 7 SDI-12
values plus the counter value. In any case, the total number may never exceed 8.

4.5.2

LTE-M

Network Coverage: Check network coverage for LTE-M at the monitoring site.

29

29

Содержание IoTa LTE-M

Страница 1: ...IoTa SensorNode User Manual...

Страница 2: ...up 11 3 2 4 Device Overview 12 3 2 5 Device Measurement Testing and Visualisation 13 3 2 6 Device Integrations 14 3 2 7 Device Configuration 14 Part IV Operation 27 4 1 Power Supply 27 4 2 Connecting...

Страница 3: ...rmation provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred This manual does not include all of the details of design productio...

Страница 4: ...rk LPWAN radio technology standard LPWAN Low Power Wide Area Network both LoRa LoRAWAN and LTE M are LPWAN technologies SDI 12 Serial Digital Interface at 1200 baud an asynchronous serial communicatio...

Страница 5: ...2022 HyQuest Solutions 5 III Scope of Delivery IoTa SensorNode Pole Mount 2 Cable Ties for pole mounting 2022 HyQuest Solutions 5...

Страница 6: ...before starting to work as well as for defects found while working Do not use the HyQuest Solutions IoTa SensorNode in areas where there is a danger of explosion The present user manual specifies env...

Страница 7: ...The hazard symbols and safety instructions on the battery label must be observed and must never be removed from the battery In case of exceptional heat development during operation the lithium ion bat...

Страница 8: ...rs IoTa SensorNodes are available in two variants one for LTE M and one for LoRaWAN communication IoTa SensorNodes are battery powered and operate autonomously for several years on a single battery ch...

Страница 9: ...antennas see Connecting an Antenna for details Counter connector M12 A coded male 4 pin screw connection use for a device that generates pulses such as a rain gauge see Connecting a Pulse Signal to th...

Страница 10: ...pon disconnecting the device will resume data transmission Downloading Configuration Software Connecting to the Device Device Selection Screen start up Device Overview Device Measurement Testing and V...

Страница 11: ...municator Once connected you might see a notification that your computer is updating its drivers Once this automatic installation is complete you will be able to see the device in HyCommunicator While...

Страница 12: ...evices Settings Menu to configure the automatic device configuration features of HyCommunicator 2 Found devices are displayed here select one to connect to that device 3 HyCommunicator version info 3...

Страница 13: ...ement Testing and Visualisation Note Description 1 Adjust the time range displayed on the graph Click to open a selection menu 2 Trigger manual measurements Single one time measurement of all enabled...

Страница 14: ...ou must be registered with the platform and have a registration key Supported Platforms datasphere data management system cloud based operated by KISTERS https www datasphere online 3 2 7 Device Confi...

Страница 15: ...e A configuration file on your computer The device type defaults reset Click on the save button to save the current configuration to either The connected device A configuration file on your computer 2...

Страница 16: ...r the configuration you have open has one or more settings that can cause the device to not operate as you intended Clicking on the INSPECT button will open a detailed dialog 2 Issues along with a bri...

Страница 17: ...device measures and transmits data Measurement Interval Value given in minutes Transmission interval Decides how many measurements are done before the device sends out its data Value given in number...

Страница 18: ...und all the devices you need you can click FINISH to stop the scan and show your sensors Supported discovered SDI 12 sensors will allow you to perform a quick setup Clicking the button will open a dia...

Страница 19: ...ed will make the device not record any battery data 2 Enable Disable the pulse counter interface Having this disabled will make the device not record any pulse counter data Every pulse on the pulse in...

Страница 20: ...n order to manually register the device through OTAA to a LoRa Network you will need to pro vide the network the device s LoRa DEUI Note 2 If unsure how to do this consult your LoRa Network s manual o...

Страница 21: ...Whether to enable adaptive data rates 3 Whether LoRa Confirmed mode should be enabled if set device will attempt failed transmissions up to 3 times 4 LoRa Class only A is supported 5 Whether device is...

Страница 22: ...000 ms 3 2 7 6 Configuration LTE Transmissions Note Description 1 Device set to use LTE transmission 2 Hostname IP and port used for data uploads 3 How many times to attempt to retry a transmission on...

Страница 23: ...7 7 Configuration GSM Note Description 1 SIM Card APN 2 If required username and password for SIM 3 Restart the GSM module every set number of transmission intervals 4 The maximum time the GSM module...

Страница 24: ...to use any network available There are a number of pre sets available to quickly get started 2 Allows setting whether LTE CAT M1 NB IoT GSM or both should be used 3 Sequence in which networks are sca...

Страница 25: ...or a specific GSM band 3 2 7 9 Configuration Time and Date Note Description 1 Current time on the device can be changed by syncing this to the PC 2 Enabled Sync sends the current UTC time Disabled Sy...

Страница 26: ...ration 3 2 7 10 Configuration Firmware Updates Note Description 1 Current firmware version Click the SELECT FIRMWARE FILE button to open a dialog where you can select a new firmware file The device wi...

Страница 27: ...The battery is help in a battery holder suitable for D cell Mono cell battery formats Inserting a sufficiently charged battery will start the device The batteries typically used in a HyQuest Solutions...

Страница 28: ...ensorNode LoRa LoRa operates with a limited payload per message This payload is fixed to 8 values 4 3 Connecting a Pulse Signal to the Counter Input M12 4 pin connector Figure 5 Pin Out of the M12 4 p...

Страница 29: ...ximum amplification allowed for the transmission This may differ between LoRa and LTE M IoTa SensorNode LoRa LoRaWAN operates in ISM Industrial Scientific and Medical band of the radio spectrum Subseq...

Страница 30: ...2022 HyQuest Solutions 30 Maintenance 5 Maintenance Clean the IoTa SensorNode by wiping with light cleaning solution and a soft cloth Replace battery as needed...

Страница 31: ...wer Supply are respected 5 Insert a new battery if the voltage is outside the specified range 6 Caution the battery voltage may drop once a load is put on the battery Only qualified technicians should...

Страница 32: ...ur return shipment 2 Please provide as much information and or clear instructions within the return paperwork This will assist our test engineers with their diagnosis 3 Please do not ship the goods pr...

Страница 33: ...LoRa LoRaWAN Regional Parameters V1 0 2 Rev B OTAA and ABP Class A EU 863 870MHz External SMA antenna connector Local Communication USB accessible via internal Micro B port for data downloads configu...

Страница 34: ...ctions must be observed 9 2 Dismantling Disposal When disposing of the units and their accessories the applicable local regulations regarding environment disposal and occupational safety must be obser...

Страница 35: ...re committed to supporting efforts to avoid and recycle waste Please consider Avoidance before recycling Recycling before disposal This symbol indicates that the scrapping of the unit must be carried...

Страница 36: ...S Group HyQuest Solutions KISTERS LATAM HyQuest Solutions NZ Ltd HyQuest Solutions Pty Ltd HyQuest Solutions KISTERS AG 49 2408 9385 0 info hyquestsolutions eu 612 9601 2022 sales hyquestsolutions com...

Страница 37: ...www hyquestsolutions com 2022 HyQuest Solutions 25 05 2022...

Отзывы: