The Hyperdrive is programmed to run the motor at a constant 12.5 amps.
The Hyperdrive also enables the motor to begin operation with a soft start
eliminating the initial power surge of a Single Phase motor.
If there is a need to run the Vacuum at lower amps because of adverse
power conditions simply press the down arrow on the keypad to reduce the
amperage sent to the motor.
When powering up the Vacuum it will automatically power up to the last
speed setting used on the keypad.
The Forward/Reverse button on the keypad is factory disabled. Never under
any circumstance should the Vacuum be run in reverse direction.
NOTE:
Do not change any Parameters of the Hyperdrive.
The Parameters of the Hyperdrive are preset for optimal operation of the
Vacuum. Changing any of the Parameters of the Hyperdrive will cause the
Vacuum to run ineffectively and/or not to operate at all.
Changing the Parameters of the Hyperdrive should only be done by a trained
and qualified technician.
The Hyperdrive is factory programmed to run off 240 Volts. If the Vacuum
shuts down and a PF Fault message is displayed on the Keypad this means
that the wrong voltage is being supplied to the drive. This commonly means
that the Vacuum is plugged into a lower power outlet – typically 208
Voltage. To rectify this simply dial down the operational hertz of the Vacuum
by pressing the down arrow on the keypad to 55Hz. If you continue to have
this problem please call our Technical Support for further instructions.
Please call our Technical Support for help if needed.
!WARNING
The Hyperdrive retains electricity even after power is disconnected!
Wait minimum 3 (Three) minutes before doing any servicing on the
Vacuum.