Diagnostics and Troubleshooting
8
XPR300
Instruction Manual
809480
285
CAN codes (500 – 503, 510 – 513 for gas connect console, 504 – 505, 514 – 515 for CAN cable and
jumper block, 507 – 508 for CAN network and bus, 600 – 602 for no CAN communication)
Multiple codes at the same time can indicate a problem with the CAN cable. If there is only one
code, the problem is more likely to be caused by what the code says (not the CAN cable).
1.
Remove the power from the cutting system. (See
Remove the power from the cutting system
2.
For
chopper-related codes
, make sure that the chopper ID cable connector is fully engaged in
J8 on each chopper (Chopper 1 and Chopper 2). If the chopper ID cable connection is good,
continue with the following steps:
a.
For code 504 alone:
Examine the CAN cable connection between Chopper 1 and Chopper 2. Look for loose
connections, bent pins, and bent sockets.
Tighten loose connections if found.
If you find bent sockets, order a new cable.
If you find a bent pin, try to straighten it. If this does not work, order a new cable.
b.
For code 503 and 504 together:
Examine the CAN cable connection between Chopper 2 and the control board (PCB 1)
on the plasma power supply. Look for loose connections, bent pins, and bent sockets.
Tighten loose connections if found.
If you find bent sockets, order a new cable.
If you find a bent pin, try to straighten it. If this does not work, order a new cable.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before doing any maintenance.
All work requiring removal of the plasma power supply panels must be
done by a qualified technician.
See the
Safety and Compliance Manual
(80669C) for more safety
precautions.
Содержание XPR300
Страница 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Страница 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Страница 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Страница 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Страница 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Страница 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Страница 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Страница 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Страница 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Страница 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Страница 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Страница 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Страница 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Страница 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Страница 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Страница 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Страница 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Страница 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Страница 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Страница 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Страница 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Страница 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Страница 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Страница 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Страница 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Страница 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...