![Hypertherm powermax900 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/hypertherm/powermax900/powermax900_service-manual_2193783026.webp)
S
PECIFICATIONS
2-5
Service Manual
Input
Phase
Input
Recommended Power Cord Gauge Size (mm
2
)
Voltage
Current (I
1eff
)
< 3 m
3 – 7.5 m
7.5 – 15 m
15 – 30 m
30 – 45 m
200 VAC
1
40A
10
10
16
25
25
230 VAC
1
35A
6
6
10
16
25
400 VAC
1
23A
4
4
4
6
10
200 VAC
3
23A
4
4
6
16
25
230 VAC
3
21A
2.5
4
6
10
16
400 VAC
3
13A
2.5
2.5
2.5
4
6
Power Cord Plugs
All 208/240/480V power supplies are shipped with a single-phase power cord and plug. To operate as a three-
phase unit, the user must obtain a power cord and plug that is certified by national or local electrical codes. The plug
should be connected to the power cord by a licensed electrician.
All 200/230/400V and 400V CE power supplies are shipped with a three-phase power cord and no plug. The
user must obtain a plug that is certified by national or local electrical codes. The plug should be connected to the
power cord by a licensed electrician.
Power Cords
If the power cord needs to be changed, use the tables below to choose the proper wire size for the appropriate length
cord. Note that the input current used to determine the cord size is I
1eff
. In the U.S., use a 3-conductor SO type cord
for single-phase, and a 4-conductor SO type cord for three-phase power supplies. In other countries, use cords that
are certified by national or local codes. Prepare the power cord wires as shown in Fig. 2-5 for non-CE power
supplies, or Fig. 2-6 for CE power supplies. Note that all 4 wires must loop through the toroid in the CE power supply.
Cap or tin the conductor leads and use a #10 terminal on the ground wire. The cord should be installed only by a
licensed electrician.
208/240/480/600V Power Supplies
Input
Phase
Input
Recommended Power Cord Gauge Size (AWG)
Voltage
Current (I
1eff
)
< 10 ft
10 – 25 ft
25 – 50 ft
50 – 100 ft
100 – 150 ft
208 VAC
1
39A
8
8
6
4
4
240 VAC
1
33A
8
8
8
6
4
480 VAC
1
19A
12
12
12
10
8
208 VAC
3
23A
8
8
8
6
4
240 VAC
3
20A
10
10
10
8
6
480 VAC
3
10A
12
12
12
12
10
600 VAC
3
8A
12
12
12
12
10
S MARK
The Powermax900 conforms to standard EN50192. The S mark indicates that the power supply and
torch are suitable for use in environments with increased hazard of electrical shock. The hand torches must have
shielded consumable parts to maintain S mark compliance.
SETUP SPECIFICATIONS
200/230/400V Power Supplies
Содержание powermax900
Страница 1: ...EN50199 EN50192 Plasma Arc Cutting System Service Manual 803150 Revision 3 ...
Страница 9: ...TABLE OF CONTENTS Service Manual vi ...
Страница 15: ...SAFETY 1 6 Hypertherm Plasma Systems 8 99 ...
Страница 21: ...SÉCURITÉ 1a 6 08 99 HYPERTHERM Systèmes plasma ...
Страница 48: ...3 21 MAINTENANCE Service Manual Notes ...
Страница 69: ...4 12 Service Manual PARTS LIST 208 240 480V ...
Страница 81: ...5 12 Service Manual PARTS LIST 200 230 400V ...
Страница 93: ...6 12 Service Manual PARTS LIST 400V CE ...
Страница 99: ...7 6 Service Manual PARTS LIST TORCH AND CONSUMABLES ...
Страница 101: ...8 2 E ELEC SCHEM PMX900 208 240 480V 013 3 326 1 OF 1 ...
Страница 102: ...8 3 E ELEC SCHEM PMX900 200 230 400V 013 3 328 1 OF 1 ...
Страница 103: ...8 4 E ELEC SCHEM PMX900 CE 400V 013 3 327 1 OF 1 ...