3-12
MAINTENANCE
powermax
600
Service Manual
Figure 3-4 Resistance Check #2 - Power Board to Chassis
Resistance Check #2 - Figure 3-4
•
Check resistance from power board connection to chassis.
> 10M
Ω
> 10M
Ω
230V and 400V
208-240V and 480V
PMX600.20
10-99