SETUP
0
3-6
powermax
1250
Operator Manual
Grounding
To ensure personal safety and proper operation, and to reduce electromagnetic interference
(EMI), the Powermax1250 must be properly grounded through the power cord according to
national or local electrical codes. Three-phase service must be of the 4-wire type with a green
or green/yellow wire for protective earth ground and must comply with national or local
electrical requirements. Single-phase service must be of the 3-wire type with a green or
green/yellow wire for protective earth ground and must comply with national or local electrical
requirements. Refer to Section 1,
Grounding safety.
Extension Cords
Use a cord that is certified by national or local codes. The cord should be installed by a
licensed electrician. Refer to the length requirements listed below.
Recommended extension cord gauge size AWG (mm
2
)
< 10 ft
10-25 ft
25-50 ft
50-100 ft
100-150 ft
< 3 m
3 – 7.5 m
7.5 – 15 m
15 – 30 m
30 – 45 m
Standard model
Input-
voltage
Phase AWG mm
2
AWG mm
2
AWG mm
2
AWG mm
2
AWG mm
2
200-208 VAC
1
6
(16)
6
(16)
6
(16)
4
(25)
2
(35)
230 VAC
1
6
(16)
6
(16)
6
(16)
4
(25)
2
(35)
480 VAC
1
10
(6)
10
(6)
10
(6)
8
(10)
8
(10)
200-208 VAC
3
8
(10)
8
(10)
8
(10)
6
(16)
6
(16)
230 VAC
3
8
(10)
8
(10)
8
(10)
6
(16)
6
(16)
400 VAC
3
10
(6)
10
(6)
10
(6)
10
(6)
8
(10)
480 VAC
3
10
(6)
10
(6)
10
(6)
10
(6)
8
(10)
600 VAC
3
10
(6)
10
(6)
10
(6)
10
(6)
10
(6)
CE model
Phase
mm
2
mm
2
mm
2
mm
2
mm
2
230 VAC
3
(6)
(6)
(10)
(10)
(10)
400 VAC
3
(6)
(6)
(6)
(6)
(10)