9 – Power Supply Component Replacement
Replacing the pressure transducer
1.
Complete the following procedures:
a.
Disconnect the power and gas supply
b.
c.
2.
Unplug the J3 connector from the back side of the power board. (See
3.
Pull the pressure transducer wires and connector through the left grommet from the fan side of the power supply.
4.
Remove the pressure transducer from the solenoid valve by pushing-to-disconnect the plastic ring against the valve
while pulling up on the pressure transducer.
5.
Insert the new pressure transducer into the valve and push down until fully seated.
6.
Route the pressure transducer connector and wires through the left grommet.
7.
Plug the pressure transducer connector into the J3 connector on the power board.
8.
Complete the following procedures:
a.
b.
Install the power supply cover
c.
Reconnect the power and gas supply.
Kit number
Description