Powermax125
Service Manual 808070
139
8 – Troubleshooting and System Tests
Fault code format – 3-nn-n
These fault codes can only be seen on the service screen.
2-11-0
Pressure sensor is open
On
On
• Check the associated wiring.
• Perform
• If necessary, replace the pressure
sensor (228689).
2-11-1
Pressure sensor is shorted
2-20-0*
Torch ID
The DSP does not recognize
the torch.
• Confirm that the torch is seated
properly in the connector.
• Inspect the connector for the proper
pin-out. See
* Perform a continuity check on the FastConnect receptacle on the power supply using the instructions in
3-nn-n
Fault
code
Description
Power
LED
Fault
LED
Fault
icon
Solutions
3-10-0
Fan speed
The fan speed is below the
minimum speed.
On
On
• Clean the fan assembly.
• Perform
3-10-1
Fan
• Check the associated wiring.
• Perform
• If necessary, replace the fan assembly.
3-20-0
Fill valve
Indicates that the fill valve is
not connected.
• Check the associated wiring.
• Perform
• If necessary, replace the electronic
regulator (228687).
2-nn-n
Fault
code
Description
Power
LED
Fault
LED
Fault
icon
Solutions
Содержание Powermax 125
Страница 1: ...Powermax125 Plasma Arc Cutting System Service Manual 808070 Revision 1 English ...
Страница 3: ...Powermax125 Service Manual 808070 Revision 1 English April 2014 Hypertherm Inc Hanover NH 03755 USA ...
Страница 6: ......
Страница 56: ...56 Powermax125 Service Manual 808070 4 Hand Torch Setup ...