Preventive maintenance
4
134
811390
Operator Manual
DynaMAX 550P/560P/575P Waterjet Pump
Prepare for storage
1.
Remove the water filters from the filter canisters. Refer to
2.
Make sure that the filter canisters are empty.
3.
Install the water filter canisters without the filters.
4.
Disconnect the compressed air supply hose from the utility panel and connect it to the
C
UTTING
WATER
IN
connection.
The
C
UTTING
WATER
IN
connection is 1/2-inch female. An adapter (not included) is necessary.
5.
Disconnect the
W
ASTE
WATER
OUT
hose from the utility panel.
6.
On the operator interface, touch the symbol on the
Prepare for Storage
screen. Refer to
The cutting water and the cooling water supply valves open.
7.
Turn
ON
the compressed air supply for a minimum of 5 minutes to dry the system.
8.
Turn
OFF
the compressed air supply.
9.
Disconnect the compressed air supply hose from the
C
UTTING
WATER
IN
connection.
10.
Water can collect in the filter canisters when the system is cleared. Make sure that the filter
canisters are empty.
11.
Install the water filter canisters with the filters.
12.
Drain hydraulic fluid from the hoses and the heat exchanger.
13.
Do this procedure for a water-cooled system.
a.
Connect the compressed air supply hose to the
C
OOLING
I
N
connection.
The
C
OOLING
I
N
connection is 1-inch NPT female. An adapter (not included) is necessary.
b.
Disconnect the
C
OOLING
O
UT
hose from the utility panel.
c.
On the operator interface, touch the symbol on the
Prepare for Storage
screen.
The cutting water and the cooling water supply valves open.
d.
Turn
ON
the compressed air supply for at least 2 minutes to dry the system.
CAUTION
High-pressure water can cause eye injuries. Wear approved eye protection when
operating or doing work near this equipment.
Do not stand over components such as tubes or valves while drying the system.
Do not dry the cooling circuit of an air-cooled system.
Содержание DynaMAX 550P
Страница 1: ...DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 REVISION 0 ENGLISH...
Страница 16: ...Product stewardship 16 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Страница 46: ...Optional equipment 2 46 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Страница 64: ...Operation 3 64 811390 Operator Manual DynaMAX550P 560P 575P Waterjet Pump...
Страница 136: ...Preventive maintenance 4 136 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Страница 146: ...Parts lists 5 146 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Страница 172: ...Troubleshooting 6 172 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Страница 222: ...Technical drawings 10 222 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Страница 223: ...Technical drawings 10 DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 223...