Keypad
-
Indicators
.....cont'd
* Not all panels have these indicators
Partial Light
-
ON when the Partial mode has been selected and only
some of the sections are armed.
-
Single flash when the system is Partially armed and Exit
timer is running.
-
Double flash when the system is armed and the Entry
timer is running. The Entry timer is started when an
Exit / Entry is activated.
-
OFF indicates partial mode is not selected.
On Light
-
Off when the system is Off
-
Single flash when the system is armed and Exit timer is
running.
-
Double flash when the system is armed and the Entry
timer is running. The Entry timer is started when an
Exit / Entry is activated.
Fire Light *
-
When the Fire input is triggered, the Fire Light will start to
Flash. If after 30 seconds the alarm has not been ac
knowledged (by entering a valid user code and ON or
OFF buttons) then an alarm will be sent to the Central
Station and the Fire Light will stay ON.
Auxillary Light *
-
The Auxillary Light is used to indicate the state of the
Panic and Tamper inputs.
-
When the Tamper input is activated the Auxillary Light
will Single Flash.
-
When the Panic input is activated the Auxillary Light will
Double Flash.
page 4