Viewing Configuration Parameters
To view system configuration parameters, select System Config from the View menu. The
configuration information is grouped into three categories. To view specific information,
click on the PCMCIA, System or Network button.

Modifying Configuration Parameters
To modify PCMCIA configuration parameters, select Configure PCMCIA from the
Configure menu. The same Hardware Setup screen which appears during the installation
process appears. Follow the instructions in the 'Hardware Setup Parameters' section to
modify these parameters.

Modifying the Network Speed
Token Ring networks operate at a speed of either 16 Mbps or 4 Mbps. To modify the
Network Speed of your SPT adapter, select Network speed from the Configure menu. The
same Network Speed screen which appears during the installation process appears. Follow
the instructions in the 'Setting the Network Speed' section to modify this parameter.

Testing the Adapter
The adapter testing utility automatically performs the following tests:

 Configuration Test
 PCMCIA Tuples Test
 Token Ring Basic Test

If a test fails, the computer stops running all other tests and displays details about the
failure.
Under normal operating conditions, there is no need to run the test program. The tests
should be run if you encounter problems during or after the installation of the Token Ring
PCMCIA card adapter drivers. The program has been designed to detect conflicts
originating from either the Token Ring PCMCIA Card, or the host computer.
To test the adapter functions of the Token Ring PCMCIA card, select Start Testing from
the Test menu.
The same Test screen which appears during the installation process appears. Follow the
instructions in the 'Running Tests' section, for displaying the test results.

Note:  If you attempt to run tests when a network driver is loaded, an error message
appears and the tests will not run.

Содержание HyperNet HYNTR70002

Страница 1: ...erNet Token Ring PC Card HYNTR70002 User Guide Information in this document is subject to change without notice All rights reserved All brand names are registered trademarks of their respective compan...

Страница 2: ...Transient Burst This product also complies with the requirements of the EMC Directive 89 336 EEC The products were tested in a typical configuration Copyright This document and all material contained...

Страница 3: ...C Network Program the Advanced Program to Program Communication APPC package and the Multi Protocol Transport Services MPTS package Features Platform independent Supports all PCMCIA 2 1 type II compli...

Страница 4: ...please observe the following precautions Discharge yourself before commencing by touching a grounded metal appliance such as the metal frame of a computer while it is tuned off but still plugged into...

Страница 5: ...o the DB 9 connector on the cable and then insert the RJ45 connector of the Type 3 UTP cable into the media filter Software Installation This section presents the software installation procedures for...

Страница 6: ...may experience memory setting conflicts To avoid this potential conflict we recommend that you carry out the following steps 1 Make a copy of the existing config sys file before editing it 2 Modify th...

Страница 7: ...e A SETUP and select OK 6 Follow the Wizard utility s on screen instructions for the setup process DOS Installation To run the Wizard utility 1 Insert the diskette into the PC diskette drive and type...

Страница 8: ...oint the driver is installed in your config sys file Your original config sys was saved as config bak The Install Network Driver screen appears Installing a Network Driver The Install Network Driver s...

Страница 9: ...sk for Windows Using the Wizard program supplied on the diskette the user may choose special custom configuration for the adapter operation or the easy to use auto configuration selection feature of t...

Страница 10: ...ken Ring adapter card into the computer s PCMCIA slot 2 The Windows 95 software automatically detects the adapter and displays the New Hardware Found dialog box If the software fails to detect the ada...

Страница 11: ...ete OPERATION Once the Token Ring PC Adapter card and its drivers have been properly installed it operates unattended This section describes the adapter test and configuration procedures Testing and C...

Страница 12: ...pears Follow the instructions in the Setting the Network Speed section to modify this parameter Testing the Adapter The adapter testing utility automatically performs the following tests Configuration...

Страница 13: ...d not define the host PCMCIA controller Recommended Actions Check the computer setup to be sure that the PCMCIA controller has been enabled or use Card and Socket Services No PCMCIA card is inserted E...

Страница 14: ...lanations are applicable refer to the relevant section below NDIS Troubleshooting When an error message is received from the NDIS driver first check the possible explanations above Then check the foll...

Страница 15: ...squeeze the plastic clips located on the side of the connector and separate it from the card Never disconnect the HyperNet PC Card by pulling on the cable If at any time during installation you experi...

Страница 16: ...Token Ring Protocols IEEE 802 2 and 802 5 Data Transfer Rates 16M or 4Mbits sec Software Included ODI workstation drivers DOS OS 2 for Novell NetWare NetWare Lite and Novell DOS 7 NDIS 2 0 1 DOS OS 2...

Страница 17: ...Filter TRMF...

Страница 18: ...fitness for use for a particular purpose The liability of Hypertec is limited to the repair or replacement of the product with a functionally equivalent or better product Hypertec is not liable for an...

Отзывы: