background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Setting charge current 
Adjust and find the desired charge current which ranges from 0.1A to 5.0A with the INC & DEC 
buttons. Press the ENTER button to confirm the setting. 
Setting battery charge voltages for A123 battery pack 
Select the proper total PACK voltage to be charged or discharged with the INC & DEC buttons.
3.3V, 6.6V, 9.9V, 13.2V,

 

16.5V, or 19.8V [Vpack] 

Setting discharge current 
Adjust and find the desired discharge current from 0.10A to 1.00A (0.01A per step) with the 
INC & DEC buttons. Press the ENTER button to confirm the setting. 
Setting battery discharge voltages for A123 battery pack 
Select the proper total battery voltages to be charged or discharged with the INC & DEC buttons 
3.3V, 6.6V, 9.9V, 13.2V,

 

16.5V, or 19.8V [Vpack] Autocut occurs automatically at 2.9V per cell. 

 

NiCd/NiMh MODE

 

(NiMh mode is the same as below, except Mode shows ‘NiMH’) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NiCd/NiMH continued next page 

 

NiCd CHARGE 
C=3.0A

 

BATT TYPE 

ENTER 

NiCd DISCHARGE 
D=0.50A      4.8 V 

 

NiCd CYCLE D->C 5 
C=3.0A   D=0.50A

 

NiCd CHARGE 
C=3.0A

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

START 

CHG   0:00   00000 
NC  +  3.0    1.200

 

NiCd DISCHARGE 
D=0.50A     4.8 V 

 

NiCd DISCHARGE 
D=0.50A     4.8 V 

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

DCH   0:00   00000 
NC  -  3.0    1.200

 

NiCd CYCLE D->C 5 
C=3.0A   D=0.50A

 

NiCd CYCLE D->C 5 
C=3.0A   D=0.50A

 

NiCd CYCLE D->C 5 
C=3.0A   D=0.50A

 

NiCd CYCLE D->C 5 
C=3.0A   D=0.50A

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

DCH   0:00   00000 
NC  +  3.0    1.200

 

NiCd CYCLE C->D 5 
C=3.0A   D=0.50A

 

START 

START 

INC 

DEC 

INC 

DEC 

INC 

DEC 

INC 

DEC 

INC 

DEC 

INC 

DEC 

INC 

DEC 

INC 

INC 

DEC 

DEC 

DEC 

INC 

ENTER 

ENTER 

ENTER 

ENTER 

ENTER 

ENTER 

A123 CHARGE 
C=5.0A     6.6Vpack

 

A123 DISCHARGE 
D=0.50 A   6.6Vpack

 

A123 CHARGE 
C=5.0A     6.6Vpack

 

A123 CHARGE 
C=5.0A     6.6Vpack

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

CHG   0:00   00000 
A1  + 3.00A   1.200V

 

A123 

 

DISCHARGE 

D=0.50 A   6.6Vpack

 

A123 

 

DISCHARGE 

D=0.50 A   6.6Vpack

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

DCH   0:00   00000 
A1  + 3.00A   1.200V

START 

INC

 

INC

 

INC

 

INC

 

DEC

 

DEC

 

DEC

 

DEC

 

INC

 

DEC

 

BATT TYPE 

START 

ENTER 

ENTER 

ENTER 

ENTER 

A123 CHARGE 
C=5.0A     6.6Vpack

 

A123 CHARGE 
C=5.0A     6.6Vpack

 

A123 DISCHARGE 
D=0.50 A   6.6Vpack

 

A123 DISCHARGE 
D=0.50 A   6.6Vpack

 

Содержание EOS 5i DP AC/DC

Страница 1: ...HYPERION EOS 5i DP AC DC EOS5IDP AD A with A123 Battery Mode User s Manual Power with Ease...

Страница 2: ...ge termination CV CC for Lithium A123 Lead Acid Batteries Cycling Modes NiCd NiMH Charge Discharge and Discharge Charge Display type 2 line 16 backlit character LCD Safety precautions KEEP CHARGER AWA...

Страница 3: ...ask your dealer to determine the proper charge current in Ampere A If the rate is given in mA note that 100mA equals 0 1A so 900mA would be 0 9A for example 4 Attach your NiMH battery to the EOS 5i O...

Страница 4: ...ER NiCd DISCHARGE D 0 50A 4 8 V NiCd CYCLE D C 5 C 3 0A D 0 50A NiCd CHARGE C 3 0A BATTERY CHECK WAIT PLEASE START CHG 0 00 00000 NC 3 0 1 200 NiCd DISCHARGE D 0 50A 4 8 V NiCd DISCHARGE D 0 50A 4 8 V...

Страница 5: ...ry voltage to be charged with INC DEC buttons 1S 3 7V single cell 2S 7 4V two cell series pack 3S 11 1V three cell series pack 4S 14 8V four cell series pack 5S 18 5V five cell series pack NOTE The EO...

Страница 6: ...ENTER button to confirm setting Displays during charge discharge and cycle Completion display When the Enter button is pressed charge or discharge will be stopped In order to move back to the main di...

Страница 7: ...ack diagnostics as one is able to see the exact balance status of the battery pack or packs when LBA10 is in NET mode To view individual cell voltages after the balance charge has been started Connect...

Страница 8: ...ESSAGES INPUT VOLTAGE ERROR Input voltage is below 11 0V or exceeds 15 0V NO BATTERY Battery not detected OUTPUT BATT REVERSE POLARITY Battery is connected in reverse polarity to Output leads OUTPUT C...

Отзывы: