Hypercable SkyMesh HYC-4011-27 Скачать руководство пользователя страница 13

 
 

www.hypercable.fr

  -  

www.e-rake.us.com

 

13 

 

 
POE – 10 / 100 / 1000 with Passive 48V DC 

 

 

 

 

 
 

Power Over Ethernet Injector Figure 
 

 

Power Over Ethernet Injector is not a waterproof unit, should not be exposed to the 
 outdoor without any protection. 

 

 

To Ethernet 

This RJ-45 port is used to connect to the 10 / 100 / 1000 Base T complied 
device such as switch, router or PC. 

To ODU 

This RJ-45 port (10 / 100 / 1000) is used to connect to the ODU. . 

DC Input 

Connect to the Power adaptor for DC input. (Passive 48V DC) 

LED Indicator 

Power LED 

 

To Ethernet 

To Radio 

DC Input 

LED Indicator (Power) 

Содержание SkyMesh HYC-4011-27

Страница 1: ...m 1 SkyMesh HYC 4011 27 5GHz 4x4 MIMO HT OFDM Radio Dual Channels Mobile Mesh network User Manual Includes install configuration and trouble shooting information for the broadband wireless access outd...

Страница 2: ...t re u le CPE par la station de base distante si le pointage est fait par une seule personne qui doit se d placer d un point a un autre il faudra inverser les fonctions base station et CPE lors du poi...

Страница 3: ...ve difficulty resolving the problem while installing or using the wireless backhaul Please contact the supplier for support Conventions This publication uses the following conventions to convey instru...

Страница 4: ...S AND BENEFITS 6 CHAPTER 2 HARDWARE INSTALLATION 9 2 1 PRODUCT KIT 10 2 2 SYSTEM REQUIREMENTS 10 2 3 MECHANICAL DESCRIPTION 11 2 4 HARDWARE INSTALLATION 14 2 5 LED INDICATORS 16 CHAPTER 3 CONFIGURATIO...

Страница 5: ...This feature provides the flexibility of deployment channel plan in high density city area Compare to the traditional Single Channel Mesh Network the Dual Channels Mobile Mesh Network design makes th...

Страница 6: ...getting worse or failed RF2 can replace the RF1 for data transmission Effective spectrum utility variable capacities with 14 channel BWs This radio has 14 channel bandwidths 2 5 3 3 5 4 5 6 7 8 10 15...

Страница 7: ...s x Mobile Mesh Network 2 ppm Frequency Stability for Mobility NLOS Transmit Power Control Supports settable transmit power levels to adjust coverage cell size ranging from max 100 to 10 of max the ad...

Страница 8: ...ops repeating Built in NMS High Efficiency in Multi hops Repeating Low Throughput dropped 40MHz Ch BW 170 Mbps 20 hops Short Latency increased 40MHz Ch BW 35 ms 20 hops Network Architecture P T P 1 0...

Страница 9: ...roduct should be handled according to all national laws and regulations Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can come into contact...

Страница 10: ...et x 1 Power Adapter x 1 Power Cord x 1 Water proof connector for SFTP cable x 1 Mounting kit x 1 Product CD x 1 Quick Installation Guide x 1 NOTE If any of the above items are missing or damaged plea...

Страница 11: ...herproof connector to connect to the To ODU side of the POE injector 2 N Jack Antenna Connector Here you can attach the N type external antenna to the 5GHz 4x4 MIMO HT OFDM MESH Radio In order to impr...

Страница 12: ...e us com 12 Antenna location definition Note 1 When you set the RF to 1x1 instead of 2x2 MIMO only Primary port works 2 RF1 Wireless 1 RF2 Wireless 2 in the configuration page RF1 Primary RF1 Secondar...

Страница 13: ...e exposed to the outdoor without any protection 1 To Ethernet This RJ 45 port is used to connect to the 10 100 1000 Base T complied device such as switch router or PC 2 To ODU This RJ 45 port 10 100 1...

Страница 14: ...sight path can guarantee the performance of the RF link Site Surveys Clear and flat area provide better RF range and data rate on the contrary physical obstructions such as trees electric tower hills...

Страница 15: ...www hypercable fr www e rake us com 15 Applications 1 With Ground Station 2 Without Ground Station...

Страница 16: ...nning mode LED1 5 blinking one by one Connected RSSI mode No LEDs on RSSI 85dBm LED1 on 81dB RSSI 85dBm LED1 2 on 76dB RSSI 80dBm LED1 3 on 71dB RSSI 75dBm LED1 4 on 66dB RSSI 70dBm LED1 5 on RSSI 65d...

Страница 17: ...e default setting is admin and password the default setting is password 3 Click on the Login button 4 After you have logged in the main page the Information Status MAP System Mesh Wireless 1 2 Managem...

Страница 18: ...www hypercable fr www e rake us com 18 Information 1 Information 2...

Страница 19: ...www hypercable fr www e rake us com 19 Status Status 1 Status 2...

Страница 20: ...radio location mark to the place wherever you want And in topology mode you can also monitor the RF settings and the link quality among the radios There are 3 ways to set the location of the radio 1 Y...

Страница 21: ...www hypercable fr www e rake us com 21 2 Enter the coordinates manually this can also be done in System Basic Setup or 3 Drag the location mark of the radio to anywhere in the map you want...

Страница 22: ...www e rake us com 22 MAP Topology Topology Map Radio info IP address MAC operating mode Frequency Topology Map Link status Data rate RSSI Distance Frequency Topology Map Multi hops repeating Topology...

Страница 23: ...gn a management Vlan ID to the radio Those PC without same Vlan ID will not be allowed to connect this radio and configure it GPS Coordinates Input the Latitude and Longitude info of the 5GHz 4x4 MIMO...

Страница 24: ...econdary Domain Name Server System STP Settings Ageing Time Configure the length of time that a dynamic entry can remain in the bridge table from the time the entry is created or last updated Spanning...

Страница 25: ...h the Time Server that you have set Time Zone You may select the appropriate local time zone for your radio from a list of all available time zones Such as below list GPS time settings Sync the time w...

Страница 26: ...ned to exploit node density in the network to extend the network lifetime and provide connectivity The following criteria have been identified as the key concepts for designing topology control protoc...

Страница 27: ...default mode is Base Station which can be scanned and connected by other CPEs CPE Perform as a client station associated to other BS Be sure that they share the same SSID when connected Bridge Point t...

Страница 28: ...an connect to Client server model Client mode Hybrid model Client mode and Unstructured peer to peer mode Hybrid model Client mode Hybrid model Client mode can connect to Client server model Server mo...

Страница 29: ...his method offer higher MAC throughput compare to A MSDU A MSDU Aggregation Aggregate MAC Protocol Data Unit The concept of A MSDU is to allow multiple MSDUs to be sent to the same receiver concatenat...

Страница 30: ...s Setup Security This is NOT Available in Mesh mode Security Cipher To prevent unauthorized radios from accessing data transmitted over the link the Encryption Settings window offers WPA2 PSK features...

Страница 31: ...ercable fr www e rake us com 31 Wireless Setup Access control This is NOT Available in Mesh mode You can enable the MAC address Access control feature and decide which mode you want to control Allow o...

Страница 32: ...he New Password field and then type it again into the Repeat New password field to confirm the new password 3 Click the Apply button to active the settings 4 You can restore to default password too by...

Страница 33: ...e Firmware from the Management page 2 Input the exact file path and name or select the file by clicking Browse button then press Upload button to upgrade the firmware 3 Please wait for few seconds If...

Страница 34: ...www hypercable fr www e rake us com 34...

Страница 35: ...ile on your computer Click Apply if you made any changes Management Reboot The Reboot screen enables you to reboot your 5GHz 4x4 MIMO HT OFDM MESH Radio if any changes are made and you want to refresh...

Страница 36: ...the Radio This will reboot the Radio If you are still unable to communicate with the Web User Interface remove the plastic cap in the left of radio s bottom Then use a stick to press in and hold the...

Отзывы: