4. Attached the antenna
Users can attach the proper antenna to the N-type connector on the PWS-M-AUnit.
To meet regulatory restrictions, the PWS-M-AUnit and the external antenna must be
professionally installed. ( Grounded and with VSWR less than 1.5)
5. Connect the Power Cable
Use the M12 connector to make a DC power cable to connect the PWS-M-AUnit and
PWS-M-Apower supply.
ATTENTION
Feed in proper voltage range DC (10~30VDC) to the PWS-M-AUnit with correct polarity
to make sure the PWS-M-AUnit works well. Please refer to below pinouts assignment for
c / - polarity, mix that might cause damage to the PWS-M-AUnit.
Model (Indoor /
PWS-M)
DC input range
Power consumption
400/500 MHz 5W
10~30V DC
Main board + RF
802.11abgn (Max. 25W)
MobiRake PWS-M-A Unit
12VDC
24VDC
Pure Tx mode
2 A.
1 A.
Pure Rx mode
1.5A
0.75A
Power cable
AWG Number
MAX current *
MOXA
21 AWG (0.723mm)
1.2~1.6A
Hypercable
20 AWG (0.812mm)
1.5~2A