![hylite MIGHTYLITE PRO MLP120 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/hylite/mightylite-pro-mlp120/mightylite-pro-mlp120_installation-and-operating-instructions-manual_2192932003.webp)
2. WIRING REQUIREMENTS
• The unit requires connection to a 230 AC 50Hz mains electricity supply.
• It is recommended that the unit is connected to the lighting circuit via a 5 amp fused spur and using Twin & Earth 2-Core
round flexible cable of at least 1mm gauge (waterproof cable should be used for outdoor installations).
• It is also advisable to install a single pole wall switch to allow easy control of the floodlight [Fig. 1].
3. FIXING THE MIGHTYLITE PRO
WARNING: Isolate the power supply before installation.
The Mightylite can be fixed in position by EITHER:
Option 1: Attaching the U bracket to the mounting surface and attaching the Mightylite to the U bracket, or
Option 2: Clamping the pipe bracket to the U bracket around a pipe or pole, and then attaching the Mightylite.
3.1. OPTION 1: ATTACHING THE MIGHTYLITE PRO VIA THE U BRACKET
If attaching the Mightylite Pro direct to a wall using the U bracket:
• Select a mounting point which is strong enough to support the weight of the Mightylite.
• Attach the Mightylite Pro to the U bracket using the two securing bolts provided [Fig.2].
• Position the unit against the mounting surface and mark the position for the U bracket, ensuring the wires can easily
reach the unit.
• Use the U bracket Fixing Holes [Fig.3] to mark the 4 drill holes required to secure the U bracket to the wall (and mark the
cable outlet location if required).
• Detach the Mightylite Pro from the U bracket, drill the wall and screw U bracket onto the wall using appropriate fixings
which are able support the weight of the Mightylite Pro.
• Once the U bracket is securely attached to the wall, offer the Mightylite Pro up to the U bracket and secure using the
securing bolts, spring washers and washers provided [Fig.2].
• Loosen the 4 screws holding the front of the connection box in place and remove.
• Feed the wire through the cable gland on the connection box gently tightening gland nut up against the gland body
[Fig. 4] to ensure the wire(s) is secured in place and no water can get though into the connection box.
• Wire the Mightylite Pro as described in Section 4.
2
Fig. 2
Fig. 3
Fig. 4
Fig. 5
PIPE
Fixing Holes
Fixing to a pipe
Mightylite
To Mains
N In
EARTH
N Out
L Out
L In
Fig.1
Fig. 6