WIRING REQUIREMENTS

Fig.1

The unit requires connection to a 230 AC 50Hz mains electricity supply.

It is recommended that the unit is connected to the domestic lighting circuit via a 

5 amp fused spur and using 2-core round flexible cable of at least 1mm

2

 gauge 

(waterproof cable should be used for outdoor installations).

It is also advisable to install a single pole wall switch to allow easy control of the 

floodlight (Fig. 1).

IMPORTANT OPERATION & MAINTENANCE INSTRUCTIONS

The Hylite Mightylite floodlight a low energy, high powered outdoor LED floodlight which is suitable for installation on solid 

walls in a range of locations including entrances, gardens, staircases, garages and outdoor parking areas

The unit requires connection to a 230 AC 50Hz mains electricity supply. 

IMPORTANT SAFETY INSTRUCTIONS

HYLITE MIGHTYLITE – INSTALLATION AND OPERATING INSTRUCTIONS

 

DO NOT position the light near flammable or combustible materials (such as wood, cloth, paper) or near flammable,  

 

combustible or explosive liquids, solids, gases or equipment.

   

 

DO NOT direct the light into a person’s eyes. This light has a very intensive light output, which if incorrectly used could  

 

cause eye damage.

   

 

ALWAYS disconnect the mains power supply before servicing or performing any maintenance.

   

 

ALWAYS maintain the light in good condition, with repairs only  undertaken by a qualified electrician

   

 

ONLY carry out repairs using genuine parts. Non-authorized parts may be dangerous and will invalidate the warranty

WARNING: THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN, AND CHECKED TO ENSURE IT IS SAFE BEFORE USING

 

PLEASE FOLLOW THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS LIGHT
    The risk of electric shock should be minimized by the installation of appropriate safety devices including the  

 

    incorporation of an RCCB (Residual Current Circuit Breaker) into the main distribution board. 
    DO NOT wire this floodlight directly into the lighting circuit. Use a switched fused spur. Cables should always be  

 

    protected against short circuit and overload by use of an RCD.

 

    Ensure the voltage marked on the product is the same as the electrical power supply to be used.
    DO NOT install the light where it is likely to be knocked or hit; in hot or humid conditions such as bathrooms, shower  

    rooms or saunas; or near an exhaust outlet e.g. boiler flue, dryer outlet.

TOOLS REQUIRED

Electric/hand-held drill

No.8 masonry drill bit

Electricians screwdriver

Large cross-head screwdriver 

Small cross-head screwdriver 

Wire cutters

 

THIS PRODUCT IS SUITABLE FOR WALL MOUNTING ONLY 

  

PARTS INCLUDED 

1 x Mightylite LED Floodlight 

1 x Connection box

1 x Cable gland

4 x Connection box screws

4 x Connection box screw covers

4 x Connection box fixing screws

4 x Connection box fixing screw covers

Fig.2

FUSE

3 AMP FUSE

TO LAMP

FROM MAINS

SUPPLY

DOUBLE-POLE SWITCHED FUSED SPUR

F

1

2

5

4

3

T

R

PIR

sensor

More sensitive

Less sensitive

L

N

SL

E

Override switch

Live

C

L1

Neutral Earth

To Mains

MightyLite

N In

N Out

L In

L Out

3-5m

Fig.5

Fig.4

Fig.3

Landscape

Portrait

FIXING THE CONNECTION BOX

WARNING: Isolate the power supply before installation.

•  Position the unit on the wall and mark the position for the connection box  
  (which can be positioned in either landscape or portrait planes [Fig. 3]).

•  Ensure the wires can easily enter the connection box through either one of the  
  knock-outs on the side of the connection box, or through the knock-out at the  
  rear of the box.

 

NOTE: It is recommended that the knock-outs on the sides of the  

  connection box are used in conjunction with the cable gland [Fig 4.] as  
  using the knock-out at the rear of the connection box will reduce the  
  weatherproof rating of the unit to IP23.

•  However, If feeding a wire(s) through the knock-out at the rear of the connection  
  box, this will need to be removed, the sealing grommet fitted [Fig.5] and the  
  wire pushed through into the connection box BEFORE it is secured to the wall. 

•  If feeding a wire(s) through the side knock-outs, it is easiest to fit the cable  
  gland to the connection box [Fig.4] BEFORE securing it to the wall, and wires  
  should enter the connection box from the sides or underneath, NOT from the top.

CHOOSING A MOUNTING LOCATION

INSTALLATION INSTRUCTIONS

•  Mount the floodlight onto solid brick or woodwork, 3 - 5m above the ground  

  [Fig. 2]

•  Avoid positioning the light near heat sources such as hot ventilator ducts, air  
  conditioning units, street lighting or traffic which may interfere with its operation.