![HygroMatik C01 KIT Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/hygromatik/c01-kit/c01-kit_manual_2192850043.webp)
Page 43
Warning:
Both the clamps that fix the steam cylinder halves and
the electrodes have sharp edges and angles that possibly could
lead to cut injuries.
8.1.1
Cleaning the Steam Cylinder
Disassembly
»
Drain residual water in the cylinder.
»
Press the on/off control switch in position "
II
".
»
Disconnect steam humidifier from power supply. Con-
trol switch OFF and remove safety fuse F1. Secure
against restart.
»
Check that unit is without power.
»
Lift steam cylinder (16+19) out of base (37) and remove
from humidifier.
»
Release its flange clamps (8) and open the cylinder.
Cleaning
Note:
When cleaning do not use acids or other chemicals!
»
Remove all scale and sludge from cylinder.
»
Remove deposit from the heating electrodes (3) by
knocking them (small amounts that remain are accep-
table).
»
Inspect the inside of the top part of the cylinder for fur-
ring and any electrical bridging (black grooves) bet-
ween the electrodes and their bushings and remove
completely by washing.
Note:
Top half of the cylinder must be replaced if electrical
bridges have penetrated deeply into the material.
»
Clean cylinder coarse strainer.
»
Restore the surface of the level electrode in the top
part of the cylinder to a bright metal condition.