Hygeniq CLEAN AIR FOGGER Скачать руководство пользователя страница 5

HYGENIQ CLEAN AIR FOGGER      

 

 5 

Safety Instructions 

 

The following symbols and terms are used throughout this manual and on the machine to alert the reader to 
safety issues and important information: 

 

Symbol 

Term 

Explanation 

 

WARNING 

Indicates a hazardous situation which, if the safety instructions are 
not followed, can lead to injuries of the operator or bystanders, light 
and/or moderate damage to the product or the environment. 

 

STRONG MAGNET 

Indicates the machine contains strong magnets. These can cause 
pacemakers to stop as well as cause damage to electronic data, for 
instance on information stored on access passes. 

 

PACEMAKER 

Indicates operators and maintenance crew wearing pacemakers 
should keep a minimal distance of 6 inch/ 15 cm. In this specific 
case operators may not use the machine as a backpack. 

 

BATTERIES 

Indicates a battery operated machine. Batteries must be disposed of 
according to your local laws and regulations. It is advisable to fully 
charge the battery before use. 

 
 
Read all instructions before using HYGENIQ CLEAN AIR FOGGER 
 

Cautions when using the machine: 

 

 
Do not operate the machine without reading and fully understanding the instructions. If the machine is 
operated incorrectly it can pose a danger to the operator and others and will invalidate the manufactures 
warranty. 
 
Before use please read and understand the following: 
 

 

A risk assessment for the works to be undertaken; 

 

MSDS Chemical Data sheet; 

 

Risk assessment for chemical use. 

 
 
Keep the HYGENIQ CLEAN AIR FOGGER upright and securely fastened at all times while in use and during 
preparation and transportation. 
 
Only use approved HYGENIQ CLEAN AIR Mist and batteries for safe use of this machine. Using other 
consumable items in the fogger invalidates the warranty and could lead to damage of the internal parts and 
could possibly pose a risk to the operator. 
 
Maintenance/service people and operators with pacemakers need to keep a distance from the integrated 
magnets in the HYGENIQ CLEAN AIR FOGGER of 6 inch/15 cm whilst maintaining and operating the fogger. 
 
Make sure the operator has been fully trained before using the machine.  
 
Avoid fogging directly on humans and animals. 
 
Ensure the machine is used in a dry environment, and do not allow water or any other liquid around the 
motor air inlet. 
 

 
 
 
 

Содержание CLEAN AIR FOGGER

Страница 1: ... Effortless 360 disinfection Model HYGENIQ CLEAN AIR FOGGER1 0 Product code E150004 Date 22 10 2020 Version A HYGENIQ Lenteweg 15 7532 RV Enschede The Netherlands 31 0 53 428 28 60 info hygeniq com www hygeniq com ...

Страница 2: ...the air in seconds It also makes disinfecting surfaces much more effective when combined with the approved HYGENIQ CLEAN AIR Mist Due to the 24V Li ion battery and refillable tank you can keep disinfecting for as long as you wish Please read the user manual carefully and become familiar with the operation and maintenance procedures Store the manual in a safe place ...

Страница 3: ...HYGENIQ CLEAN AIR FOGGER 3 Content PREFACE 2 Packing List 4 Safety Instructions 5 Product Description 6 Setup 9 Operation 11 Maintenance 133 ...

Страница 4: ...HYGENIQ CLEAN AIR FOGGER 4 Packing List ...

Страница 5: ... FOGGER Cautions when using the machine Do not operate the machine without reading and fully understanding the instructions If the machine is operated incorrectly it can pose a danger to the operator and others and will invalidate the manufactures warranty Before use please read and understand the following A risk assessment for the works to be undertaken MSDS Chemical Data sheet Risk assessment f...

Страница 6: ...HYGENIQ CLEAN AIR FOGGER 6 Product Description ...

Страница 7: ...y voltage DC24V Duration of battery 1 Hour Charger input voltage AC100 250 Voltage Charging time 1 Hours 50 minutes Speed of spray 175 100ml minutes Hose length 1 2 meters Droplet size 20 150µm Spray nozzles 0 3x3mm 0 5mm 0 8mm 1 0mm Theoretical capacity per tank 12000m3 Machine power 450W Spray distance 5 6 meters Pump DC24V 5W 100ml minute Main body material LDPE Spray handle material Aluminum ...

Страница 8: ...HYGENIQ CLEAN AIR FOGGER 8 ...

Страница 9: ...ecure it in a upright position Unscrew the cap of the liquid tank and pour the required amount of the approved HYGENIQ CLEAN AIR Mist into the tank Insert the liquid tank back to the machine which should also be placed in an upright position Note 1L of HYGENIQ CLEAN AIR Mist covers approximately 3650 m3 3 Insert the battery to the machine Open the battery housing door and slide the fully charged b...

Страница 10: ... handle Select the appropriate nozzle for the application Nozzle size Droplet size Spray distance Duration 3 5L Appliccation 0 3mm 3x 20µm 5 6m 35minutes indoor 0 5mm 30µm 5 6m 30minutes indoor 0 8mm 40µm 5 6m 25 30minutes indoor 1 0mm 60µm 5 6m 20 25minutes outdoor ...

Страница 11: ...Turning on the machine Step 2 Press the button and start fogging Step 3 Turning off the machine 234 1 Press the button once The nozzle starts to fog The cumulative timer starts Power switch slide to On position The power indicator will be illuminated The cumulative timer displays the hours of operation up to the last usage 234 Press the button again the pray nozzle will stop fogging The cumulative...

Страница 12: ...ob Secondary effect is that the particles get heavier and via laws of gravity descend This way the descending layer of mist works as a membrane filtering all other unwanted particles such as microdust out This results in a completely antibacterial filtered and purified air composition in the room Specific risk points like door handles light switches and other manual touch points can be targeted di...

Страница 13: ...o exceed 4 hours of continuous use 4 Ensure the machine is always used upright and in a dry environment and do not allow water or any other liquid around the motor air inlet 5 Spray nozzles need to be stored in the small tool box together with the screw driver The tool box can be hooked on to the backpack harness spring hook 3 nozzles in the tool box and 1 in the spray handle 6 If there is any iss...