6300-LR Series
Sensor Operated Mixing Faucet
Maintenance Tasks
PRESSURE RELEASE VALVE REPLACEMENT
1. Disconnect power by disconnecting the AC adapter
or battery pack underneath the faucet.
2. Unscrew the Body Set Screws and with an upward
motion, pull the the upper faucet body off of the
faucet base.
3. Disconnect the connector for the Pressure Release
Valve Assembly.
4. Unscrew the Pressure Release Valve Assembly and
remove it from the upper faucet body.
5. Install the new Pressure Release Valve and reas-
semble the faucet in reverse order.
CONTROL MODULE (P.C. BOARD) REPLACEMENT
1. Disconnect power by disconnecting the AC adapter
or battery pack underneath the faucet.
2. Unscrew the Body Set Screws and with an upward
motion, pull the the upper faucet body off of the
faucet base.
3. Disconnect the connector for the Pressure Release
Valve Assembly.
4. Unscrew the Retaining Rods and pull them up and
out from the faucet base.
5. Remove the Control Module.
6. Install the new Control Module and reassemble the
faucet in reverse order.
For further questions, please call Hydrotek Technical
Support at (800) 922-9883.