20
Upflow Cabinet Water Softener Installation
Brine Elbow
Assembly
Water Pipe Outlet
Bypass assembly
Outlet
Inlet
Water Pipe Inlet
Drain Elbow
Assembly
Floor drain
Optional
Pipes Fixed
Structure
5/8” Overflow Line
AC120V/10A
Current Protect Socket
5/8” Drain Line
Outlet
NOTICE - THERE ARE INLET
AND OUTLET LABELS
ON THE VALVE. PLEASE
MAKE SURE TO PLUMB AS
SHOWN HERE
Inlet
CAUTION!
Never insert drain line
directly into a drain, sewer line, or trap.
Always allow an air gap between the drain
line and the wastewater to prevent the
possibility of sewage being back-siphoned
into the conditioner.
NOTE
Waste connections or drain
outlet shall be designed and
constructed to provide for
connection to the sanitary
waste system through an
air-gap of 2 pipe diameters
or 1 inch (22 mm) whichever
is larger.
*NOTE
Check local plumbing codes
in regards to requirements
for use of Check Valve or
back flow prevention or
vacuum breaker
Cold (Raw water)
Cold (Filtered water)
Cold (Raw water)
Check Valve
Water Heater
Hot (Soft Water)
Upflow Water Softener
Filter
In
In Out
Out
Cold (Soft Water)
To Outside Faucet
In
Out
*
CABINET WATER SOFTENER INSTALLATION
Connect Softener to the House Plumbing
Any solder joints near the valve must be done before connecting any piping to the valve. Always leave at least 6” (152 mm)
between the valve and joints when soldering pipes that are connected to the valve. Failure to do this could cause damage to the valve.