1. If your hot water tank is electric, turn off the power to it to avoid damage to the element
in the tank.
2. If you have a private well, turn the power off to the pump and then shut off the main wa-
ter shut off valve. If you have municipal water, simply shut off the main valve. Go to the
faucet, (preferably on the lowest floor of the house) turn on the cold water until all pres-
sure is relieved and the flow of water stops.
3. Locate the softener tank and brine tank close to a drain where the system will be in-
stalled. The surface should be clean and level.
4. Connect the inlet and outlet of the softener using appropriate fittings. Perform all plumb-
ing according to local plumbing codes.
Use a ½” minimum pipe or tubing size for the drain line
ON COPPER PLUMBING SYSTEMS BE SURE TO INSTALL A GROUNDING
WIRE BETWEEN THE INLET AND OUTLET PIPING TO MAINTAIN GROUND-
ING.
Any solder joints near the valve must be done before connecting any piping to the valve.
Always leave at least 6" (152 mm) between the valve and joints when soldering pipes that
are connected to the valve. Failure to do this could cause damage to the valve.
5. Connect the drain hose (10 ft included) to the valve and secure it with a hose clamp (also
included). Run the drain hose to the nearest laundry tub or drain pipe. This can be ran
up overhead or down along the floor. If running the drain line more than 20 ft overhead,
it is recommended to increase the hose size to 3/4”. NEVER MAKE A DIRECT CONNEC-
TION INTO A WASTE DRAIN. A PHYSICAL AIR GAP OF AT LEAST 1.5” SHOULD BE USED
TO AVOID BACTERIA AND WASTEWATER TRAVELLING BACK THROUGH THE DRAIN
LINE INTO THE SOFTENER.
6. Using the Allen Key (included), place the unit in the bypass position. Slowly turn on the
main water supply. At the nearest cold treated water tap nearby remove the faucet
screen, open the faucet and let water run a few minutes or until the system is free of any
air or foreign material resulting from the plumbing work.
7. Make sure there are no leaks in the plumbing system before proceeding. Close the water
tap when water runs clean.
8. Open the brine tank / cabinet salt lid and add water until there is approximately 3" (75
mm) of water in the tank. Do not add salt to the brine tank at this time.
9. Proceed to start up instructions.
Note: The unit is not ready for service until you complete the start-up instruc-
tions.
Installation Instructions
6
Содержание 785 MBTO
Страница 7: ...Installation 7 ...
Страница 16: ...Brine Tank Res Up Feeder Assembly 80030022 64 OZ PRO RESCARE 16 ...
Страница 18: ...Control Valve Exploded View 18 ...
Страница 20: ...Power Head Exploded View 20 ...