Hydrotech Water 565 HIMTLC-100 Скачать руководство пользователя страница 9

9  

 

Setting Current Time 

 

1.  If screen is locked, press “

 

MENU

 

for 3 seconds to unlock.  Press “

 

MENU

” 

again

 

to

 

enter

 

level

 

one

 

programming

 

mode

 and adjust CURRENT TIME. 

2. Press 



 

SET/REGEN

” 

to

 

adjust

 hours.  When you have entered the change value mode, the curser will blink.  Press “

 or 

 

UP

 

OR

 

DOWN

 

arrows to change the hour values.  Press “



 SET/REGEN

 

again to accept the hour value and advance 

to change the minutes value.  Press ““

 or 

 

UP

 

OR

 

DOWN

” 

arrows

 

to

 

change

 the minute values.  Press “



 SET/

REGEN

 

again to accept the minute values and advance to adjust the AM/PM values.  Press “

 or 

 

UP

 

OR

 

DOWN

 

to 

change the AM/PM value.  Press “



 SET/REGEN

 

again to accept the AM/PM value and exit.  When you have exited the 

change value mode, the curser will stop flashing. 

 

Setting Current Date 
 

1. Press 

 

DOWN

” 

to

 

advance

 

to

 

CURRENT

 

DATE.

 

2.  Using the same procedure as setting the time, press “



 SET/REGEN

 

to enter value change mode. 

 

Setting Number of People 

1. Press 

 

DOWN

” to 

advance

 

to

 

NUMBER

 

OF

 

PEOPLE.

 

2.  Press the “



 SET/REGEN

” 

to

 

change

 

the

 value.  Press up or down arrows to change the values. 

 

Setting Water Hardness 

 

1. Press 

 

DOWN

 

to advance to WATER HARDNESS. 

2.  Press the “



 SET/REGEN

” 

to

 

change

 

the

 value.  Press “

 or 

 

UP

 

OR

 

DOWN

 

to change the values. 

 
 
 

Setting Vacation Mode 
 

1. Press 

 

DOWN

 

to advance to VACATION MODE. 

2.  Press the “



 SET/REGEN

” 

to

 

change

 

the

 value.  Press “

 or 

 

UP

 

OR

 

DOWN

 

to change the values. 

 

Exiting Level One User Program Mode 
 

At any time, press the “

 MENU”

 

to accept all changes and return to main page display. 

 

 

OPTIONS

DESCRIPTION

1

CURRENT

 

TIME

This

 

option

 

is

 

the

 

current

 

time

 

of

 

day.

2

CURRENT

 

DATE

This

 

option

 

is

 

the

 

current

 

date.

  

The

 

date

 

is

 

used

 

to

 

track

 

the

 

last

 

time

 

the

 

system

 

regenerated.

3

NUMBER

 

PEOPLE

This

 

value

 

is

 

the

 

number

 

of

 

people

 

living

 

in

 

the

 

home.

  

It

 

is

 

used

 

to

 

calculate

 

the

 

amount

 

of

 

water

 

needed

 

for

 

daily

 

use

 

and

 

the

 

reserve

 

capacity

 

of

 

the

 

system.

4

WATER

 

HARDNESS

This

 

value

 

is

 

the

 

maximum

 

water

 

hardness

 

in

 

grains

 

per

 

gallon

 

of

 

the

 

raw

 

water

 

supply.

  

It

 

is

 

used

 

to

 

calculate

 

the

 

system

 

capacity.

Yes

No

Level

 

I

 

User

 

Program

 

Mode

PARAMETER

5

VACATION

 

MODE

This

 

function

 

may

 

be

 

activated

 

by

 

the

 

user

 

during

 

a

 

prolonged

 

absence

 

such

 

as

 

vacation.

  

The

 

system

 

will

 

perform

 

a

 

brief

 

backwash

 

and

 

rinse

 

based

 

on

 

the

 

advanced

 

setting.

  

The

 

purpose

 

is

 

to

 

keep

 

the

 

water

 

fresh

 

in

 

the

 

softener

 

tank

 

and

 

plumbing

 

system.

Level

 

I

 

User

 

Programming

 

Содержание 565 HIMTLC-100

Страница 1: ...ngs during installation by applying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quali...

Страница 2: ...reating water that is microbio logically unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimi...

Страница 3: ...s Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night...

Страница 4: ...ange previously manufactured products or to note the change Factory Settings High Capacity Salt Used Per Regeneration 12 0 lbs 18 0 lbs 24 0 lbs 36 0 lbs Water Used Regeneration 64 3 gal 90 3 gal 124...

Страница 5: ...f a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to plug the in cluded transformer into is needed within 6 feet of the softener The transformer has...

Страница 6: ...s could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This ca...

Страница 7: ...Installation 7...

Страница 8: ...ny button to advance to the REFILL position Check that the valve is filling wa ter into the brine tank Allow the valve to refill for the full amount of time as dis played on the screen to insure a pro...

Страница 9: ...r Hardness 1 Press DOWN to advance to WATER HARDNESS 2 Press the SET REGEN to change the value Press or UP OR DOWN to change the values Setting Vacation Mode 1 Press DOWN to advance to VACATION MODE 2...

Страница 10: ...ates The regeneration cycle lasts up to 180 minutes During this time you may hear water running intermittently to the drain About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 GAL...

Страница 11: ...ion Step Name Description 1 Back Wash Fresh water is introduced to the bottom of the tank flowing upwards expanding the ion exchange resin to rinse out any dirt or small particles to the drain and to...

Страница 12: ...e only crystal water softener salt Check the salt level monthly It is important to main tain the salt level above the water level To add salt simply lift the salt lid and add the salt directly into th...

Страница 13: ...rol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Remov...

Страница 14: ...he BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DLFC...

Страница 15: ...o form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid San...

Страница 16: ...Brine Tank Res Up Feeder Assembly 80030022 64 OZ PRO RESCARE 16...

Страница 17: ...antity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP...

Страница 18: ...Control Valve Exploded View 18...

Страница 19: ...Control Valve Parts List 19...

Страница 20: ...Power Head Exploded View 20...

Страница 21: ...flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean par...

Страница 22: ...replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifica...