Hydrotech Water 565 HIMTLC-100 Скачать руководство пользователя страница 1

565

 

HIMTLC

 

Softener

 

&

 

Tannins

 

Reduction

 

System

 

Owners Manual 

REVISION # 

 

REVISION DATE  May 4,2015 
546601 

1.  Read all instructions carefully before operation. 
2.  Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified 

lubricant to all seals. 

3.  This system is not intended for treating water that is microbiologically unsafe or of unknown 

quality without adequate disinfection before or after the system. 

Canadian

 

Head

 

Office

 

655

 

Park

 

St.

 

Regina,

 

SK

 

S4N

 

5N1

 

 

U.S.

 

Head

 

Office

 

8437

 

10th

 

Avenue

 

North

 

Golden

 

Valley,

 

MN

 

55427

 

   

Содержание 565 HIMTLC-100

Страница 1: ...ngs during installation by applying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quali...

Страница 2: ...reating water that is microbio logically unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimi...

Страница 3: ...s Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night...

Страница 4: ...ange previously manufactured products or to note the change Factory Settings High Capacity Salt Used Per Regeneration 12 0 lbs 18 0 lbs 24 0 lbs 36 0 lbs Water Used Regeneration 64 3 gal 90 3 gal 124...

Страница 5: ...f a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to plug the in cluded transformer into is needed within 6 feet of the softener The transformer has...

Страница 6: ...s could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This ca...

Страница 7: ...Installation 7...

Страница 8: ...ny button to advance to the REFILL position Check that the valve is filling wa ter into the brine tank Allow the valve to refill for the full amount of time as dis played on the screen to insure a pro...

Страница 9: ...r Hardness 1 Press DOWN to advance to WATER HARDNESS 2 Press the SET REGEN to change the value Press or UP OR DOWN to change the values Setting Vacation Mode 1 Press DOWN to advance to VACATION MODE 2...

Страница 10: ...ates The regeneration cycle lasts up to 180 minutes During this time you may hear water running intermittently to the drain About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 GAL...

Страница 11: ...ion Step Name Description 1 Back Wash Fresh water is introduced to the bottom of the tank flowing upwards expanding the ion exchange resin to rinse out any dirt or small particles to the drain and to...

Страница 12: ...e only crystal water softener salt Check the salt level monthly It is important to main tain the salt level above the water level To add salt simply lift the salt lid and add the salt directly into th...

Страница 13: ...rol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Remov...

Страница 14: ...he BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DLFC...

Страница 15: ...o form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid San...

Страница 16: ...Brine Tank Res Up Feeder Assembly 80030022 64 OZ PRO RESCARE 16...

Страница 17: ...antity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP...

Страница 18: ...Control Valve Exploded View 18...

Страница 19: ...Control Valve Parts List 19...

Страница 20: ...Power Head Exploded View 20...

Страница 21: ...flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean par...

Страница 22: ...replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifica...

Отзывы: