Troubleshooting

Moby Controller is 

ON but fla ps do not 

operate on manual

Moby Controller is 

ON but fla ps do not 

operate on manual

Go to System 

Information.               

Do you notice N2K 

error and Temperature 

Offline?

1) Open the air unit.

 

2) When buttons ↑↓←→ 

are pressed, do you 

notice the red lights on 

the PCB on? 

1) Is there power supply 

to the air unit? 

2) Are the fuses ok?

3) Does the PCB has 

power supply?

Use a jumper wire 

between COM and 

LDRU, RDLU,DN,UP.

Do you notice relevant 

red lights on?

1) Reset or replace the fuses.

2) Check the wires which are 

connected to PCB and 

transformer.

3) Replace the transformer.

When the red lights are 

on, does the compressor 

work?

Replace air unit PCB.

When the red lights are 

on, do the relevant 

solenoids operate?

1) Check for replacement the 

compressor relay and 20A 

fuses.

2) The compressor is burned.

Yes 

No

Do you get the 

relevant output?

No

Yes 

Yes 

No

Yes 

No

Yes 

No

Burned solenoid or 

pilot.

Air leakage by faulty 

flap or air unit.

Yes

No

NMEA Network 

communication failure 

due to cabling or PCB 

fault.

Yes

No

Содержание AIR UNIT II

Страница 1: ...Hydro Tab Marine Engineering 1 Hydrotab BT Series INSTALLATION MANUAL AIR UNIT II NMEA 2000 NMEA 0183 Hydro Tab Marine Engineering...

Страница 2: ...gn patents pending Declaration of conformity This product conforms to the following Electromagnetic Compatibility EMC regulations and standards for use in marine environments CE EN 60945 Technical inf...

Страница 3: ...I Installation 4 Pneumatic Connection 5 Technical Data Dimensions 5 Air Unit II Direct Installation Diagram 6 Air Unit II Installation Diagram on existing NMEA network 6 Air Unit II Electrical Diagram...

Страница 4: ...ick Installation Guide Drilling Pattern The air unit must be installed in a compartment free of explosive or flammable gases Please ensure that the air unit is installed according to the IP30 limitati...

Страница 5: ...er 250 W Air compressor type Brushless oil free Voltage 24 V Amps 11 A In Line Fuse 30 A Max pressure 4 bar Air Unit II DataSheet A B C Connect the push in fitting After you install the hose through t...

Страница 6: ...000 Flybridge OPTIONAL controller CABLE 3m MF Moby Controller Direct Installation Diagram Air Unit II CABLE 10m FF In case a new NMEA 2000 instrument to be added a proper NMEA Network must be built US...

Страница 7: ...OM 12 24V V4 V3 V2 V1 RM 12V 12 24V 12 24V NMEA 2000 T1 M Compressor 500 AIR N2 V2 1 F1 F1 3A 24V DC 230V DC 24V DC 230V DC 24V DC 230V DC C5 Timer Switch 12V Tr1 1 2 3 4 LEFT RIGHT 1 2 3 4 LEFT RIGHT...

Страница 8: ...NMEA 2000 1 29 PNE 01249A COMPRESSOR 24VDC 1 30 PNE 01249B TRANSFORMER 1 31 PNE 01249C COMPRESSOR FILTER 1 4 1 32 REV 00582 VENTURI MANIFOLD 1 33 RUB 00162 PCB RUBBER BASE 1 46 45 20 39 38 19 24 23 18...

Страница 9: ...umper wire between COM and LDRU RDLU DN UP Do you notice relevant red lights on 1 Reset or replace the fuses 2 Check the wires which are connected to PCB and transformer 3 Replace the transformer When...

Страница 10: ...tab gr product registration In case the dealer sells separate units of Interceptors Air Units and Controllers that constitute a full system that is not initially sold as a complete system by Hydrotab...

Страница 11: ...Hydro Tab Marine Engineering 11 Notes...

Страница 12: ...Hydro Tab Marine Engineering 12 4 Papazoglou str GR 17778 Athens Greece email info hydrotab gr website www hydrotab gr REV B Hydro Tab Marine Engineering...

Отзывы: