LOCATING THE OZONE INJECTOR MANIFOLD
1.
The manifold
must be placed at or near the operating equipment
2.
Place the Ozone Injector Manifold into the return system plumbing as the last item in the equipment sequence
before the water returns to the jets or wall fitting. Reference diagram #2 for typical plumbing layout, correct
manifold location and water flow direction.
Note that your system provider may have different arrangement for pump filter and heater sequence, however this
manifold must be placed after the water has passed through all equipment
WARNING!
Placing this manifold in any other location i.e. in between the filter pump or in front of the heater will
cause operational problems and equipment damage including loss of pump prime, reduced filtration, and heater
damage that is not covered under warranty.
3.
The manifold must be plumbed in the correct direction for water flow. The arrow label placed on the manifold
shows the direction water must flow through the manifold for proper operation. (Label arrow should not be
pointing toward any other component in the plumbing system)
4.
Connect manifold to system pipe with PVC glue. DO NOT mount manifold upside down or vertically
INSTALLING CHECK VALVE KIT WITH TUBING
Follow instructions included with the Ozone Check Valve Kit to connect supply tubing between the Ozone Injector
Manifold and cabinet mounted Plus Ozone™ generator barb.
Some extended length injector manifolds (not shown) come with a bracket and bolt assembly to help support the
additional plumbing weight. When provided, install bracket and secure to the plastic base with screws as shown in
Dia.# 3
Dia #3