LOCATING THE OZONE INJECTOR MANIFOLD  

1.

 

The manifold 

must be placed at or near the operating equipment                                                                          

2.

 

Place the Ozone Injector Manifold into the return system plumbing as the last item in the equipment sequence 
before  the  water  returns  to  the  jets  or  wall  fitting.  Reference  diagram  #2  for  typical  plumbing  layout,  correct 
manifold location and water flow direction.   

Note  that  your  system  provider  may  have  different  arrangement  for  pump  filter  and  heater  sequence,  however  this 
manifold must be placed after the water has passed through all equipment 

WARNING!

 Placing this manifold in any other location i.e. in between the filter pump or in front of the heater will  

cause  operational  problems  and  equipment  damage  including  loss  of  pump  prime,  reduced  filtration,  and  heater 
damage that is not covered under warranty.   

3.

 

The manifold must be plumbed in the correct direction for water flow. The arrow label placed on the manifold 
shows  the  direction  water  must  flow  through  the  manifold  for  proper  operation.  (Label  arrow  should  not  be 
pointing toward any other component in the plumbing system) 

4.

 

Connect manifold to system pipe with PVC glue. DO NOT mount manifold upside down or vertically  

INSTALLING CHECK VALVE KIT WITH TUBING                                                                                                             

Follow instructions included with the Ozone Check Valve Kit to connect supply tubing between the Ozone Injector 
Manifold and cabinet mounted Plus Ozone™ generator barb.  

Some extended length injector manifolds (not shown) come with a bracket and bolt assembly to help support the 
additional plumbing weight. When provided, install bracket and secure to the plastic base with screws as shown in  
Dia.# 3 

 

 

 

 

 

 

Dia #3 

 

 

 

 

         

 

Содержание PLUS OZONE

Страница 1: ...d into the upper cabinet Reference Dia 1 SAVE THESE INSTRUCTIONS Kit includes Tools and supplies needed 1ea Ozone Injector Manifold Timer with second hand 1ea Ozone Check Valve Kit 16oz water bottle O...

Страница 2: ...ge including loss of pump prime reduced filtration and heater damage that is not covered under warranty 3 The manifold must be plumbed in the correct direction for water flow The arrow label placed on...

Страница 3: ...3...

Страница 4: ...4 ADJUSTING OZONE VACUUM FLOW...

Страница 5: ...ter through the ozone injector DIA 3 View the water return fitting Dia 4 and adjust the valve handle until very small ozone bubbles are detected coming from the return fitting TYPE 1 TIPS A properly a...

Страница 6: ...red vacuumed from the generator The water bottle technique is an easy measurement method and excellent substitution for SCFH measuring equipment TROUBLE SHOOTING Ozone is not being delivered through v...

Страница 7: ...nce Filtration Settings in your operation manual to adjust filter cycle duration that will directly affect the length of time the Plus Ozone operates each day ABOUT Plus Ozone is a Corona Discharge CD...

Страница 8: ...on as described in Disable Plus Ozone option immediately if found to have water present in tubing between the check valve and ozonator Contact your system supplier for replacement valve and tubing 3 P...

Страница 9: ...9 85 0021Q Rev 02 02 12 18...

Отзывы: