background image

22 

 

TOPSIDE PANEL DISPLAY MESSAGES 

OHH/HTR TEMP LMT/OH/HL (solid or flashing) 
Overheat – Spa has shut down. One of the sensors has de-
tected 48°C (119°F) at the heater. 

 
DO NOT ENTER WATER! 

Remove cover and allow water to 

cool. Reset system by pressing any topside control panel pad. 
If system does not reset, shut off power and call your dealer. 

 
POSSIBLE CAUSES OF OVERHEATING 
• filter cycle too long or overlapping (pump running for 
extended periods of time) 
• isolation/gate valves partially closed 
• extremely hot weather/high ambient temperatures 
• defective sensor wire 

 

POSSIBLE CAUSES OF OVERHEATING 
• filter cycle too long or overlapping (pump running for 
extended periods of time) 
• isolation/gate valves partially closed 
• extremely hot weather/high ambient temperatures 
• defective sensor wire 
 

ICE/FREEZE COND 
Potential freeze condition detected. Pumps and blower will 
automatically activate when temperature drops to 4°C (39°F) 
regardless of operation mode. 
 
 

Prr 
Indicates high-limit or water temperature sensor is non-
functional. 
 
SnA/SENSOR A SERVICE RQD 
Spa has shut down – sensor plugged into Sensor ‘A’ port not 
working. 
 
SnB/SENSOR B SERVICE RQD 
Spa has shut down – sensor plugged into Sensor ‘B’ port 
notworking. 
 
SnS/SENSOR SYNC 
Sensors are out of balance – If topside display alternates 
between temperature and SNS, then occurrence may be tem-
porary and will correct itself. The spa shuts down completely 
when the SNS message is flashing on the display. 
 
HFL/HTR FLOW LOW 
A substantial difference in temperature between the sensors 
has been detected – this could indicate a flow problem. 
Check water level in spa and add if necessary, also ensure 
the filter is clean. If water level is okay, make sure that pumps 
are primed and all gate valves are fully opened. 
 
LF/LOW FLOW 
Persistent low flow problem – displays on the fifth occurrence 
of an HFL message within a 24 hour period. Heater circuit is 
deactivated but other spa functions continue to operate nor-
mally. Check water level in spa and add if necessary, also 
ensure the filter is clean. If water level is okay, make sure that 
pumps are primed and all gate valves are fully opened. Press 
any topside panel pad to reset. 

Содержание Serenity Hot Tubs

Страница 1: ......

Страница 2: ...Display Messages 22 23 Optional Variable Air Therapy System Control 23 Jet and Feature Operation 24 25 Jet Identification Chart 24 Jet Water Flow Adjustment 24 Jet Air Flow Adjustment 24 Interchanging...

Страница 3: ...ns in this manual before electrically connecting your hot tub and adding water The following pages contain valuable information and pointers that will save you both time and money as well as help you...

Страница 4: ...F THIS SPA OR HOT TUB 13 CHILDREN SHOULD NOT ENTER A HOT TUB WHERE THE WATER TEMPERATURE EXCEEDS BODY TEMPERATURE 37 C 98 6 F 14 DO NOT ALLOW CHILDREN TO SUBMERGE THEIR HEAD UNDER WATER 15 NEVER OPERA...

Страница 5: ...PREVENT UNAUTHORIZED ACCESS BY CHILDREN TO AVOID ACCIDENTS ENSURE THAT CHILDREN CAN T USE THE SPA UNLESS THEY ARE SUPERVISED AT ALL TIMES 2 RISK OF INJURY THE SUCTION FITTINGS IN THIS SPA ARE SIZED TO...

Страница 6: ...plashing water inside the home For those who choose an outdoor location hot tub operating temperatures can be adjusted to match the season In colder months many owners will operate their hot tub in th...

Страница 7: ...cal plugs outlets and lights within 1 5m 5ft of the hot tub must be G F C I protected Con sult your electrician or local electrical au thority for further details Access to the hot tub must always be...

Страница 8: ...r or not the tub is being installed in an area with freeze thaw conditions Hydro pool does not recommend back filling full in ground or partial in ground installations Non freezing climates it is suff...

Страница 9: ...company for a tilt and load tow truck with a pulley winch system to pull the skid from the larger trailer to the lower profile tow truck flat bed The hot tub can be gently slid off the low profile tr...

Страница 10: ...WG Canada Europe No 8 AWG USA 8 All field installed metal components such as rails ladders drains or other similar hardware within 3 m 10 ft of the hot tub shall be bonded to the equipment grounding b...

Страница 11: ...ccordance with the National Electrical Code or the Canadian Electrical Code and all Federal State Provincial and local codes and regula tions in effect at the time of installation Hydropool highly rec...

Страница 12: ...C D Circuit Breaker including ampere sizing and selection of conductor size and type must be performed by a qualified electrician in accordance with National Regional and Local Codes and Regulations i...

Страница 13: ...ush the button to release the scent into the hot tub and repeat to add more liquid scent as desired please note by turning the button clockwise you can lock it so that any accidental pushing of the bu...

Страница 14: ...OD touch or iPAD If your hot tub comes with this option installed you need to activate the App Store Icon from your IPOD menu Type in Balboa Water Group into the search field to find the application a...

Страница 15: ...connections and plumbing for minor leaks In the event of a leak ensure all union con nections and pump plugs are tight and all o rings gaskets are in place STARTING Before applying voltage to power u...

Страница 16: ...t do this more than 5 times Important Under NO circumstances should the pump s be allowed to operate without priming beyond 5 minutes as this may not only cause unwarrantable damage to the pump it may...

Страница 17: ...Be sure that the pump is primed before exiting this mode TEMPERATURE CONTROL FUNCTIONALITY AND ADJUSTMENT SET TIME After the system exits PRIMING MODE it will ask you to SET TIME See the instructions...

Страница 18: ...1 ILLUM KEY WHICH CONTROLS THE LIGHTING AND ACTIVATES THE LOW LEVEL PROGRAMMING TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROLLS THROUGH THE MENUS TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROL...

Страница 19: ...WHICH CONTROLS THE LIGHTING AND ACTIVATES THE LOW LEVEL PROGRAMMING TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROLLS THROUGH THE MENUS TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROLLS THROUGH TH...

Страница 20: ...speed is already operating the 1st press of the pad puts the pump directly into high speed At the main screen begin by pressing TEMP READY MODE READY mode will circulate the water every 30 minutes usi...

Страница 21: ...e pump or blower is turned off or times out The pump and ozone generator will run for 20 minutes or more depending on the system OPTIONAL OZONATOR The ozonator operates during FILTER CYCLES only when...

Страница 22: ...ter temperature sensor is non functional SnA SENSOR A SERVICE RQD Spa has shut down sensor plugged into Sensor A port not working SnB SENSOR B SERVICE RQD Spa has shut down sensor plugged into Sensor...

Страница 23: ...okay make sure that pumps are primed and all gate valves are fully opened Press any topside panel pad to reset RUN PMPS PURG AIR Priming mode occurs when spa is first powered up or when power has bee...

Страница 24: ...ntrol is fully opened For maximum operating efficiency the air controls must remain closed when your hot tub is not in use INTERCHANGING JET INSERTS A great feature for custom tailoring the jets in yo...

Страница 25: ...tub is equipped with a diverter valve It allows you to direct the flow of the water to different zones in your hot tub ALWAYS return the valve handle to the middle position be fore exiting the hot tub...

Страница 26: ...ng upward on the handle 2 Remove the connector cover prior to plugging in your audio source Always keep the cover on when the docking station is not in use 3 Center the device over the Docking Station...

Страница 27: ...micals with each other prior to adding to hot tub water Add only one chemical to the water at a time Always add chemicals to water and not vice versa Chemicals may be corrosive so handle with care and...

Страница 28: ...e bicarbonate and hydroxide compounds present in the water that deter mines the ability or capacity of the water to resist change in pH Also known as the buffering capacity 11 ALKALINITY BOOSTER raise...

Страница 29: ...s in the future Increase filter cycle time Laundry detergent residual in swimwear Prevent by running an extra rinse cycle on washing machine or re rinse well by hand Excess organic contaminants Some o...

Страница 30: ...dge in a filter cartridge cleaning solu tion Rinse thoroughly and if possible allow to dry before re installing Hydropool recommends purchasing a second filter so that while the first is cleaning the...

Страница 31: ...o remove remaining dirt particles Do not use a wire brush or other devise to clean cartridge element Do not put in dishwasher or washing ma chine RE INSTALLATION 11 Place the cartridge filter back int...

Страница 32: ...polished using a soft cloth and acrylic cleaner available at your Hydropool Retailer Important Do not use detergents the re maining residues will adversely affect water chemistry making it difficult...

Страница 33: ...a petroleum based lubricant as this will cause premature dete rioration of the lock seal PROTECTING YOUR CABINET WOOD FINISH Some HYDROPOOL hot tub cabinets are made from Western red cedar and are fac...

Страница 34: ...ery important ALL water is re moved from the hot tub plumbing before adding Turn pump on for only a few seconds to circulate the anti freeze Unthread and disconnect all unions in the support equip men...

Страница 35: ...partial messages try resetting the system by turn ing power to the hot tub off waiting a few minutes then turning power on again If this does not reset the system contact your local Hydropool retailer...

Отзывы: