IX. maINtENaNcE

Before maintenance, shut off the power supply. Because it is dangerous that the pump 
would start abruptly when in automatic mode.

1.- Important notice for daily checking.

1)  If pressure, voltage, vibration, noise is different from that of normal, it predicates 

there is something wrong with the pump. Stop the pump and repair it at once. In 
addition, it is suggested to use spare pump to prevent from sudden case.

2)  The max temperature of bearing is 80°C . If the motor shell can be tou¬c hed by 

hand, it is normal, or it should be checked after stop.

3)  The normal leakage of mechanical seal is 3m1 per hour. When running, if leakage is 

bigger than this and bigger and bigger, stop it at once.

4)  In the case of correct installation and pipe work, if there is strong vib-ration when 

running, it indicates that pump receives big force from pipe or the base screws are 
loose. Stop and check at once.

2.- When pump running, please refer to the following.

1)  If the pump running exceeds the nominal pressure(head), it will ove-rburden. 

Therefore, the motor will be burned. 
Important notice: Must not close the discharge valve when running.

2)  The metal sound will be heard when pump running in high pressure. This is the 

character of the gas-liquid pump, not the malfunction.

3)  The pump should not be started frequently. For the pump with motor power less 

than or equal to 4kw,the number of startup shall not more than 100 per hour. For 
the pump with motor power more than 4kw,the number of startup shall not more 
than 20 per hour. If the startup is too frequent,the device should be checked and 
adjusted to reduce the start-stop frequency.

4)  When power cut, must switch off the pump to prevent from pump ru-nning 

suddenly when power is supplied, which will be dangerous.

3.- The storage is as follows when the pump stop working for a long time.

1)  In winter, if pump stops, must take anti-frozen steps and drain the wat¬er in pump 

to prevent pump casing from broken.

2) Spare pump should be run periodically, so it is ready for work. 

4.- Wearing parts of pump

1) The pump parts should be replaced if the following case happened.

Note: The above normal replacement period is the period of replacement for normal usage.
When ordering spare parts, please advise the pump model indicated in the pump name plate.

X. aSSEmBlE aND DISaSSEmBlE

Please follow up the following steps to disassemble and assemble. 

 
1.- Disassemble

1) Disassemble pump cover screws, take apart pump cover;
2)   Loose impeller fixing screws, take the impeller from the shaft. If the impeller is 

difficult to take it out, fit the screws to two screw holes, pull the impeller out;

3) Take apart thekey from shaft, wipe off the fixing trail;
4) Take apart the rotating ring of mechanical seal;
5)  Loose and take off the screws which are fixing the volute to the pump station 

flange, take apart the volute. The stationary part of mechanical seal can also be 
taken apart with the volute. Note that not scratch the face of m¬echanical seal.

2.- Assemble 

Reverse the disassemble steps can assemble a pump. But take note of the following.

1)  The spring hook of mechanical seal should be in the mechanical seal fixing groove 

of the impeller. The rubbing part of mechanical seal should be cleaned by clean and 
soft cloth. Be careful not scratch the rubbing face;

2)  Impeller should be fit between casing and cover. In addition, before disassemble, 

wipe off the fixing trail. The clearance between impeller and casing is adjusted  
as follows.

     Fit the impeller on the shaft, push it toward to the casing until it touches the casing. 

Tight the impeller fixing screws a little, then hammer the shaft point slightly, the 
impeller is moved by reverse force. When the clearance is adjusted correctly, fit  
the cover, rotate the shaft. If the shaft can rotate s¬moothly, tighten the impeller 
fixed screws.

3) Replace 0 ring, gasket
4) Replace all wore out parts.
5)  The screws should be tightened evenly, do not tighten one and then tighten  

another one.

6) After installation finished, rotate the shaft, it should not be choked or loose or tight.

Wearing parts

Standard of replacement

Normal replacement period

Mechanical seal

Leakage exceeds required amount

Once a year

Bearing

There is abnormal noise or grease leaks

Once in two or three years

Gasket or 0 ring

When routing checking 

Once in two or three years

Содержание 20HQX-1

Страница 1: ...HQX Stainless Steel Self suction Gas liquid Mixing Pump Operation Manual HYDROO Pump Industries SL NDROO SERIES ...

Страница 2: ...ll the flow parts of the pump are made of stainless steel by precise molding technology Name type or model batch or serial number Name Stainless steel self suction gas liquid mixing pump Model HQX B Series HQXL B Series Standards used including number title issue date and other relative documents Machinery directive 98 37 EC Machinery directive 2006 42 EC Standard EN809 1998 A1 2009 Place of Issue...

Страница 3: ...ication Gas suspension treating equipment ozone water making equipment heavy oxygen enriched water making equipment and biological treating e quipment Transfer of heating or cooling medium for various temperature adju sting devices Various filters Sucking from underground tank or high pressure transferring low vi scosity liquid such as gasoline diluents all kinds of solvent Misting treatment of cl...

Страница 4: ...6 7 V DRAWING HQX B 080701 HQXL B 110102 ...

Страница 5: ... 47 140 200 190 G2 G11 2 12 91 Model Size mm Weight kg HA HB HC HG AB AC L LA LB LC LD LE LF S D E 20HQXL 1 198 228 141 265 265 225 532 55 20 228 388 135 G3 4 G1 2 ø8 5 26 20HQXLB 1 198 228 141 330 265 225 532 55 20 228 388 135 G3 4 G1 2 ø8 5 36 25HQXL 2 220 255 150 284 275 235 610 60 28 293 453 85 145 G1 G3 4 ø11 36 25HQXLB 2 220 255 150 410 275 235 610 60 28 293 453 85 G1 G3 4 ø11 48 40HQXL 6 25...

Страница 6: ... the gas inlet valve when manual operation 2 Close inlet valve gradually when the vacuometer indicates negative pressure 100mmhg 0 3kgf cm2 open gas suction valve Open the check valve of the outlet pressure meter adjusting outlet pipe controlling valve until arrive to the set outlet pressure 3 Adjust inlet pipe controlling valve gas suction valve outlet pipe co ntrolling valve little by little unt...

Страница 7: ...p parts should be replaced if the following case happened Note The above normal replacement period is the period of replacement for normal usage When ordering spare parts please advise the pump model indicated in the pump name plate x Assemble and disassemble Please follow up the following steps to disassemble and assemble 1 Disassemble 1 Disassemble pump cover screws take apart pump cover 2 Loose...

Страница 8: ...pe or check the seal to see if there is gas leakage Water leaks from pump 1 The mechanical seal is not fit well 2 The mechanical seal is broken or wears out 1 Refit the mechanical seal 2 Replace mechanical seal Too much noise 1 The motor bearing wears out 2 The impeller is blocked 1 Replace bearing or motor 2 Refit the impeller or send pump to HYDROO The motor temperature is too high smokes out an...

Страница 9: ... pumping partners 201905 IOM HQX EN subject to amendments HYDROO Pump Industries SL Ctra Girona Banyoles km 10 17843 Palol de Revardit Catalonia Spain Tel 34 972 394 654 E mail info hydroo com www hydroo com ...

Отзывы: