Hydronic P720 Скачать руководство пользователя страница 2

Hydronic Air Driven Pumps & Intensifiers 

P720 Installation, Use and Maintenance Booklet               08-21-09 

Page 2 

 
 

Introduction 

 
This handbook is intended to give the operator the basic instructions for the use and 
maintenance of the pump. The air hydraulic pump operator must read this handbook 
before putting the pump into operation. After correctly installing the pump, keep this 
manual stored in a safe place. If you have difficulty in understanding any part of this 
handbook, contact Hydronic Corporation. Regular servicing and correct use of the 
pump are fundamental in obtaining optimum performance over its life. When 
contacting our service center, specify the pump model and serial number; this will help 
us to respond quickly and effectively. 

 
Guarantee 

 
Hydronic pumps are guaranteed both for the quality of materials used and for overall 
design. The warranty runs for six months of normal use at eight hours per day and five 
days per week. The warranty itself does not cover seals or defects arising out of 
operating with unsuitable fluids or at pressures above the specified maximum. The 
guarantee cannot cover pumps that may have been tampered with. Defective goods 
must be sent to Hydronic Corporation at Farmington Hills or to the distributor covering 
the area, freight pre-paid in either case. Any pump returned to us must be 
accompanied by a full written description of such faults or defects as have been 
discovered. Please also ensure that the pump’s serial number is attached to the 
paperwork. 

 
Identification Plate 

 

 

Содержание P720

Страница 1: ...troduction Guarantee and Identification Plate Description Air Operated Pressure Release Valve Startup Procedures Description of Working Parts Storage and Disposal Fault Finding Maintenance and Weights Spare Parts Hydronic Corporation 2034 Fruit St Algonac MI 48001 United States of America 810 794 4935 www hydroniccorp com ...

Страница 2: ...p model and serial number this will help us to respond quickly and effectively Guarantee Hydronic pumps are guaranteed both for the quality of materials used and for overall design The warranty runs for six months of normal use at eight hours per day and five days per week The warranty itself does not cover seals or defects arising out of operating with unsuitable fluids or at pressures above the ...

Страница 3: ...gulator unit having minimum flow capacity of 30 scfm plus a pressure gauge in order to ensure the pump has sufficient air energy to work correctly and provide the hydraulic performance you expect Hydraulic System Valves pipes hoses and accessories should all correspond to maximum working pressure of the pump used and be of a size that will fulfill flow requirements Bear in mind the minimum of bore...

Страница 4: ...nk with oil and try the pump out to ensure that it working properly This operation must be carried out by qualified personnel Disposal If the pump is to be scrapped treat as a special type of waste Dismantle it and divide it into materials of the same type and dispose of them in accordance with the local laws and regulations in your state Description of the standard pump components A Air inlet 1 8...

Страница 5: ...atic valve will be used to direct regulated air pressure either to the pump or to the pressure release valve In this way the pump is started with the system intact and stopped with the oil pressure vented safely to tank Varieties of pneumatic valve may be used including solenoid and lever allowing the power unit to be situated away from the operator The adjustment C1 may be needed when the pilot a...

Страница 6: ...ntil primed and oil comes through to the output port Now shut off the air supply to the pump and securely connect the hydraulic circuit Switch on the air supply again and allow the pump to run in order to bleed any air out of the hydraulic circuit Fault Finding Chart Fault Cause Remedy 1 Pump does not 1 1 Low pressure in 1 1 Clear any blockage or cycle or runs slowly compressed air line restrictio...

Страница 7: ...epair work can only be made when pneumatic and hydraulic pressure has been released and you are sure that no pressure remains in the circuit Delivery of the pump Transport All the material shipped including the detached parts has been thoroughly checked before being consigned to the forwarding agent The pump is shipped in double corrugated cardboard packaging which assures protection of the produc...

Страница 8: ...s orders must always be accompanied by the following information A The pump model B The pump serial number C Year of construction all this data is given on the nameplate D The part numbers E The quantity required F The name of the part All this data is given in the parts list A clear and correct statement of this data will allow our after sales service to respond quickly and appropriately Every sp...

Страница 9: ...ING 1 12 5 064 0025 SPRING 1 13 3 094 0006 SCREW 2 14 5 064 0026 SPRING 1 15 5 093 0001 SILENCER 1 16 5 018 0029 JACKET 1 17 5 045 0014 RING NUT RATIO 1 100 1 17 5 045 0015 RING NUT RATIO 1 70 1 17 5 034 0005 RING NUT RATIO 1 40 1 17 5 045 0016 RING NUT RATIO 1 20 1 17 5 034 0047 RING NUT RATIO 1 10 1 18 5 014 0011 BUSHING RATIO 1 100 1 18 5 014 0012 BUSHING RATIO 1 70 1 18 5 014 0013 BUSHING RATI...

Страница 10: ... 5 046 0002 CENTERING 1 30 5 064 0023 SPRING 1 31 3 076 0010 BALL 1 32 3 052 0005 WASHER 1 33 5 071 0003 SUCTION CONNECTOR 1 36 3 051 0002 O RING 1 52 5 094 0305 COUPLING 1 52 1 3 094 0403 SCREW 1 80 3 094 0009 SCREW 1 81 3 051 0072 O RING 1 82 3 051 0039 O RING 2 83 3 094 0007 SCREW 1 84 5 041 0005 FILTER 1 85 3 072 0103 WASHER 6 107 5 034 0054 CONNECTOR 1 Seal Kits Ratio Code S720 10 N SK 1 10 3...

Страница 11: ... 094 0305 Coupling 1 53 5 090 0002 Pipe 1 54 5 066 0009 Pivot 1 56 5 094 0306 Coupling 1 57 5 034 0098 Head 1 59 5 011 0001 Pivot 1 60 5 050 0002 Air Diaphragm 1 61 5 008 0010 Disk 1 62 5 008 0011 Washer 1 63 3 031 0051 Nut 1 64 5 064 0027 Spring 1 64 1 5 064 0003 Spring 1 65 5 033 0001 Disk 1 66 5 086 0005 Head 1 67 3 094 0008 Screw 6 68 3 031 0004 Nut 1 70 3 005 0024 Seal Ring 1 71 3 051 0198 O ...