10
Cool Caddie User Manual
www.HydromistUSA.com
Water sprays from nozzles
after system is shut down.
Anti-drip not functioning.
Check integrity of anti-drip stopper and
spring. Replace nozzles if necessary.
Filter housing leaks.
O-Ring failure.
Inspect placement and integrity of O-ring.
Replace if necessary.
Figure 9 – Location of filter housing and circuit breaker reset button.
Figure 10 – Location of pump filter screen.