9.  Slide the Clamping Bolt (13-C) into a Washer (13-A).

10. Insert the Clamping Bolt (13-C) into the curved slot in the Mounting 

Bracket (11), through the lower hole of the Upper Mounting Pole (1) and 

out through the curved slot on the other side of the Mounting Bracket (11).

11. Slide a Washer (13-A) over the end of the Clamping Bolt (13-C), then 

thread the Locking Nut (13-D) onto the threaded end of the Clamping 

Bolt (13-C), and tighten the nut until the Mounting Bracket (11) is snug 

against both sides of the Upper Mounting Pole (1).

WARNING: Before connecting the fan wires to building wires, turn the 

power breaker to OFF or otherwise disable power from the building wires.

12. Press the other end of the 1/4-Inch Nylon Tube (14) into the the 3/8-Inch x 

1/4-Inch Reducer fitting. Make sure to push the tube into the smaller end of 

the fitting, ensuring that the tube is inserted completely into the fitting. The 

3/8-Inch side of the Reducer fitting connects to a misting pump.

13. Use one Wire Nut (13-F) each to connect wire pairs together, making 

sure to screw them on tight and have no bare wire exposed.

a.  Brown fan wire is HOT and connects to black building wire.

b.  Blue fan wire is NEUTRAL and connects to white building wire.

c.  Green/yellow striped fan wire is GROUND and connects to green 

solid or bare copper building wire.

~or~

bare 

copper

HOT

NEUTRAL

GROUND

Operation

Power & Speed Control

The ceiling fan model does not have a built-in switch and does not have 

speed controls. It is intended to be connected to building wiring with a self-

Содержание CentraMist series

Страница 1: ...CentraMist Ceiling Fan Manual 360o Misting PN F10 01 018 black F10 01 019 white HydroMistUSA com ...

Страница 2: ...tp www HydroMistUSA com 2018 HydroMist All rights reserved Updated 09 27 18 The purpose of this document is to be informative and as such is not guaranteed to be error free HydroMist takes steps to ensure that our information is correct and as error free as is reasonable Please let us know if you believe you found a typo or error ...

Страница 3: ...ts Warnings 5 What s In the Box 6 Assembly 8 Operation 9 Power Speed Control 9 Misting 10 Winterizing Instructions for Misting Fan Heads 10 Replacement Parts 10 Available CentraMist Fan Models 10 HydroMist One 1 Year Limited Warranty 11 ...

Страница 4: ...HydroMist HydroMistUSA com 4 ...

Страница 5: ...e reconnecting to power outlet Never insert fingers or any other objects through grills while fan is operating Do not operate mist in freezing weather conditions Misting components must be winterized to prevent damage Motor bearings are sealed and do not require additional lubrication When securing power cables on outdoor installations loop them below and back up to the power outlet This makes any...

Страница 6: ...HydroMist HydroMistUSA com 6 What s In the Box 5 6 4 8 12 11 9 A B C D E F G 10 1 7 2 3 13 14 ...

Страница 7: ...10 Fan Head with Misting Nozzles nozzles already installed 1 11 Black Mounting Bracket 1 12 1 4 Inch Nylon Tube 1 13 Mounting Bracket Hardware Set 1 13 A Washers 4 13 B Clevis Pin 1 13 C Clamping Bolt 1 13 D Locking Nut 1 13 E Cotter Pin 1 13 F Wire Nut 3 13 G Lag Screw 4 14 3 8 Inch x 1 4 Inch Reducer 1 Fan and upper mounting pole should both be either black or off white not mixed Lower mounting ...

Страница 8: ...r fitting on the misting ring 5 Attach the Mounting Bracket 1 1 to an appropriate ceiling mounting location using 4 ea of Lag Screw 13 G Supplied Lag Screws 13 G are designed to secure the mounting bracket into a wooden ceiling joist For other materials please purchase appropriate mounting hardware WARNING Mounting Bracket must be secured to a ceiling joist or other surface that will support 60 po...

Страница 9: ...ding wires 12 Press the other end of the 1 4 Inch Nylon Tube 14 into the the 3 8 Inch x 1 4 Inch Reducer fitting Make sure to push the tube into the smaller end of the fitting ensuring that the tube is inserted completely into the fitting The 3 8 Inch side of the Reducer fitting connects to a misting pump 13 Use one Wire Nut 13 F each to connect wire pairs together making sure to screw them on tig...

Страница 10: ...hose and rings to completely drain which prevents breakage due to freezing 2 Clean the nozzles with 50 50 diluted vinegar and warm water Do not use harsh chemicals as they will harm the o rings 3 Store nozzles in a small container or baggie to prevent them from collecting dust while not in use 4 For harsh winter weather conditions cover or store the fan heads to prevent them from becoming damaged ...

Страница 11: ...copy of the purchase invoice within 30 days of purchase In General If a HydroMist product fails because of defect in material or workmanship under normal use and maintenance within one year from date of purchase we will at our option and after inspection repair or replace the defective product About Your Warranty Fan products like all mechanical devices need periodic parts and service to perform w...

Страница 12: ...Document PN F10 18 001 ...

Отзывы: