Pump does not run or
just hums.

1. Line circuit breaker may be

off, blown or loose.

2. Water level in sump may be

too low to activate automatic
float or diaphragm switch. 

3. Pump and/or switch cord plug

may not be making contact 
in receptacle.

4. If pump is using the series

(piggyback) cord plug, the
two plugs may not be plugged 
tightly together.

5. Float may be stuck. Be sure

float operates freely in basin.

6. If the unit is being operated

by the optional float control
switch, unplug the pump from
the piggyback receptacle and
plug the pump directly into
the power source. If the pump
starts each time it is plugged
directly into the receptacle
and does not start each time

when plugged into the piggy-
back switch with the float
raised up to a start position,
replace the complete piggy-
back switch assembly and
retest with new assembly.

7. If all symptoms check OK,

motor winding may be open;
take to authorized service
center for check.

Pump runs but does not 
deliver water.

1. Check valve may be installed

backward. Arrow on valve
points in direction of flow.

2. Discharge gate valve, if used,

may be closed.

3. Pump may be air locked. Start

and stop several times by
plugging and unplugging cord.
Check vent hole in pump case
for plugging.

HYDROMATIC pumps have
a small air vent hole in the
impeller cavity to let out
trapped air. If this hole
becomes plugged, pump may
air lock. To break the air lock,
use a small screwdriver to
clear hole in the impeller 
cavity.

As a secondary precaution in
installations of this type —
1 ⁄ 16" hole should be drilled
in the   discharge pipe below
the check valve. The check
valve should be 12 to 18
inches above pump discharge.
Do not put check valve
directly into pump discharge
opening.

NOTE: In sumps where the
pump is operating daily, air
locking rarely occurs.

4. Pump head may be too high.

Pump cannot deliver water
over 25' vertical lift.
Horizontal distance does not
affect pumping, except for 
friction loss through the pipe.

5. Inlet in pump base may be

clogged. Remove pump and
clean out openings.

6. Impeller or volute openings

may be plugged or partially
plugged.  Remove pump and
clean out.

Pump runs and pumps out
sump but does not stop.

1. Float is stuck in up position.

Be sure float is not hung up
and operates freely in basin.

2. Switch contacts may be stuck;

replace switch.

8

4

0

0

10

20

30

0

10

20

30

40

50

60

0.0

0

2

4

6

8

10

12

1.0

2.0

3.0

Head, meters

Head, feet

Capacity, US GPM

liters/second

cu meters/hr

.30 HP

Содержание W-A1

Страница 1: ...ller Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual Submersible Sump Pump W D V A1 W A1 V A1 D A1 ...

Страница 2: ...ock This pump has not been investi gated for use in swimming pool areas General Information Pump Warning 2 Make sure float automatic models hangs free It should not come into contact with side or bottom of sump pit 3 Make sure sump is free of string cloth nails gravel etc before installing pump 4 Do not set pump directly on the bottom of sump if it is not solid Raise the pump by placing bricks or ...

Страница 3: ...lications and prod uct information contact your HYDROMATIC distributor Your pump warranty is void If power cord has been cut If pump has been used to pump mud cement tar abrasives or chemicals If pump has been used for pumping of hot water above 120 F If pump has been dismantled by other than authorized Hydromatic service center or distributor W A1 D A1 V A1 ...

Страница 4: ...pen take to authorized service center for check Pump runs but does not deliver water 1 Check valve may be installed backward Arrow on valve points in direction of flow 2 Discharge gate valve if used may be closed 3 Pump may be air locked Start and stop several times by plugging and unplugging cord Check vent hole in pump case for plugging HYDROMATIC pumps have a small air vent hole in the impeller...

Страница 5: ... in pump base may be clogged Remove pump and clean out openings 2 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out 3 Pump impeller may be partially clogged causing motor to run slow resulting in motor over load Clear impeller 4 Fuse size or circuit breaker is too small 5 Defective motor stator return to authorized Hydromatic service center for verification ...

Страница 6: ...6 W A1 D A1 V A1 Typical Installation ...

Страница 7: ...1 5 Diaphragm Switch 20 1 NOT 13869 510 5 Vertical Switch 10 1 SHOWN 13869 520 5 Vertical Switch 20 1 1 26230A000 Ring Handle 1 2 14077 000 1 Pipe Plug 1 3 Motor Housing 1 4 Stator Seal Plate Rotor Shaft Assembly 1 5 139 014 1 Seal Ring 1 6 14770 005 1 Pan Screw 5 6 7 8521 101 1 Bottom Plate 1 8 14770 002 1 Pan Screw 6 5 9 8520 002 1 Base 1 10 8498 003 1 Impeller 1 11 21607A001 Shaft Seal 1 12 147...

Страница 8: ...r and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 S...

Отзывы: