The following steps should be
performed by an authorized
Hydromatic service center 
or distributor.

Note: Use extreme caution
around electrical devices.
Electrical shock may occur.

1. Before removing pump from

the sump, check to be sure the
problem is not a blown fuse,
tripped circuit breaker or a
power cord not completely
inserted into the receptacle.

2. If the unit is being operated by

an optional control switch,
unplug the pump from the
piggyback receptacle and plug
the pump directly into the
power source. If the pump
starts each time it is plugged
directly into the receptacle and
does not start each time when
plugged into the piggyback
switch with the float raised or
diaphragm pressed up to a start
position, replace the complete
switch assembly and retest
with new assembly.

3. If pump fails the above two

steps, remove pump and
switch from power source to
avoid electrical shock. Then
pull the pump from the sump
by the handle. Sandblast, if
possible, any dirt or trash 
from the outside of the pump
before dismantling.

4. If the above tests have not

resolved the problem, it may
be in the electrical components
of the pump. Starting with the
power cord, inspect for cuts or
nicks in the insulation. If the
cord is damaged – replace it!

5. Using the ohmmeter, check 

the resistance of the motor
windings by connecting one
lead clip to each electrical
“flat” prong on the power cord

pump mud, cement, tar,
abrasives or chemicals.

If...

pump has been used for
pumping of hot water 
(above 120° F).

If...

pump has been dismantled
by other than authorized
Hydromatic service center
or distributor.

12.To ensure that the pump is

properly installed, fill basin
with enough water to activate
pump. Allow the pump to go
through several on-off cycles
to assure satisfactory operation.

13.Use pump partially or

completely submerged for
pumping waterlike liquids
(temperature to 140°

F).

The SKV50 will pump solid
materials up to 2" (spherical)
in diameter.

Caution:  Do not pump 
flammable liquids, strong 
chemicals or salt water.

Your pump warranty is void...

If...

power cord has been cut.

If...

pump has been used to

Read the following instructions
carefully before replacing any
parts. Reasonable care and safe
methods should be practiced.
Check local codes and
requirements before installation.
Only competent electrician
should make the installations.

Pump
Servicing

Содержание SKV50M1

Страница 1: ...ewage Ejector Pump SKV50 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Страница 2: ... solid Raise the pump by placing bricks or concrete blocks underneath it 5 Use steel or plastic pipe for all connecting lines between pump and sewer outlet Note Some city regulations do not allow installing a pump with plastic pipe Check local regulations 6 In applications where the pump may sit idle for months at a time it is recommended that the pump s be cycled every month to ensure the pumping...

Страница 3: ...olved the problem it may be in the electrical components of the pump Starting with the power cord inspect for cuts or nicks in the insulation If the cord is damaged replace it 5 Using the ohmmeter check the resistance of the motor windings by connecting one lead clip to each electrical flat prong on the power cord pump mud cement tar abrasives or chemicals If pump has been used for pumping of hot ...

Страница 4: ...ft and rotor assembly If the bearing is rusted or feels rough when turned it should be replaced as in Step 13 12 Coat the replacement seal 6 with a thin oil dielectric same as in motor housing coating and use a plastic pusher to install the seal 6 into the seal plate 10 Do not use any sharp instruments that may damage the seal Do not chip scratch or mar the carbon face 13 If ball bearing replaceme...

Страница 5: ...yback receptacle and plug the pump directly into the power source If the pump starts each time it is plugged directly into the receptacle and does not start each time when plugged into the piggyback switch with the float raised up to a start position replace the complete piggyback switch assembly and retest with new assembly 7 If all symptoms check OK motor winding may be open take to authorized s...

Страница 6: ...r volute openings may be plugged or partially plugged Remove pump and clean out 5 Pump impeller may be partially clogged causing motor to run slow resulting in motor overload Clear impeller Fuse blows or circuit breaker trips when pump starts 1 Inlet in pump base may be clogged Remove pump and clean out openings Check vent hole in pump case for plugging Hydromatic pumps have a small air vent hole ...

Страница 7: ...ll 230V Motor 1 14 14981 001 1 Pipe Plug 1 15 14623 010 1 Cord Assy 16 3 10 115V 1 15 14623 020 1 Cord Assy 16 3 20 115V 1 15 14623 210 1 Cord Assy 16 3 10 230V 1 15 14623 220 1 Cord Assy 16 3 20 230V 1 17 6000 053 1 Wire with Terminal 1 18 6000 061 1 Wire with Terminals 2 19 75 005 1 Cord Nut 1 20 139 014 1 Cord Grommet 1 21 13666 000 1 Ground Strap 1 FOR AUTOMATIC OPERATION Not 13967 011 5 Piggy...

Страница 8: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Отзывы: