SUBMERSIBLE
SOLIDS HANDLING PUMP

Models S4T, S8L, S8LA, and S12L

10/10

Item # E-03-503

320 Frame

Part # 5625-503-1

© 2010 Pentair Pump Group, Inc.  

Installation and Service Manual

NOTE! To the installer: Please make sure
you  provide  this  manual  to  the  owner  of
the equip ment or to the responsible party
who maintains the system.

For use with product
built with USEM motor.

Содержание S12L Series

Страница 1: ... 503 320 Frame Part 5625 503 1 2010 Pentair Pump Group Inc Installation and Service Manual NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system For use with product built with USEM motor ...

Страница 2: ...ave impellers manually rotated 6 revolutions after setting non operational for 3 weeks or longer and prior to electrical start up Pump The submersible pump is supplied for three phase only and for 460 and 575 volts Pump is supplied with 35 feet of power cord and or 35 feet of auxiliary control cord Longer cable lengths can be furnished but must be specified at time of order Power cable is three Ge...

Страница 3: ... panel for making connections An extra set of diagrams is included so that one set can be used in the sump when making connections The size wire to use from panel to sump depends on motor size and distance in feet Be sure each wire is checked so that a wrong connection will not be made An ohmmeter or Megger can be used to check wire continuity Installing Float Switch Controls The controls are supp...

Страница 4: ... and 3 Starting System 1 Turn H O A switch to Off position and then turn on main circuit breakers 2 Open all discharge valves and allow water to rise in sump 3 Turn H O A switch to Hand position on one pump and notice operation If pump is noisy and vibrates rotation is wrong To change rotation interchange any two line leads to motor 3ø only Do not interchange main incoming lines If duplex system c...

Страница 5: ...ry to completely dismantle pump as stator and housing can be As the motors are oil filled no lubrication or other maintenance is required If a seal failure unit is used no attention is necessary as long as the seal shows satisfactory operation If seal failure is not used the pump should be lifted once every two years and the oil drained from the seal chamber to check for water If the pump is used ...

Страница 6: ...sible oil Fill chamber until oil covers top of the windings Leave air space in the top for expansion Use Permatex on plug threads Replacing Seals and Bearings 1 Drain all oil from motor chamber and seal chamber as described 2 Remove motor housing as described 3 Remove bolts that hold seal chamber to pump housing Use back off screws to break loose With hardwood block tape end of impeller to loosen ...

Страница 7: ...ective If pump still does not start trouble is in the alternating relay Replace with new relay Pump runs but will not shut off 1 Pump may be air locked Turn pump off and let set for several minutes then restart 2 Lower float control may be hung up in the closed position Check in sump to be sure control is free 3 Selector switch may be in the Hand position Pump does not deliver proper capacity 1 Di...

Страница 8: ...8 Motor End Components ...

Страница 9: ...9 S4T S8L S8LA S12L Wet End Components ...

Страница 10: ...15175 300 1 BAIL LIFTING 1 F3 05454A030 WASHER LOCK 3 4 4 F4 05454A027 WASHER LOCK 5 8 2 F5 15174 000 1 BRACKET MOUNTING 2 F6 19105A033 SCREW CAP HEX SST 5 8 2 51700 068 7 Seal Kit S 51700 368 7 Carbide Seal Kit C 24709110000 Paraffinic Oil O ORDERING REPLACEMENT PARTS Product improvements are made from time to time The latest part design will be furnished as long as it is interchangeable with the...

Страница 11: ...75 002 1 3 23394A001 3 8662 011 1 13769 003 5 14161 012 5 14161 603 1 50 230 3 1150 64 005 1 2 2498 009 1 3 8675 000 1 3 11667 000 1 9 8662 004 1 13769 001 5 14160 012 5 14160 003 1 50 460 3 1150 64 005 1 2 2494 000 1 3 2498 007 1 3 8675 000 1 3 8790 000 1 9 8662 004 1 13769 005 5 14160 012 5 14160 003 1 50 575 3 1150 64 005 1 2 2498 007 1 3 8675 000 1 3 23394A001 3 8662 004 1 13769 003 5 14160 01...

Страница 12: ... 2 13766 037 5 S4T7500M5 4 75 575 3 2 4 13 13532 109 2 13766 037 5 S4T10000M4 4 100 460 3 1 0 4 14 13532 105 2 13766 036 5 S4T10000M5 4 100 575 3 1 0 4 14 13532 105 2 13766 036 5 S4T12500M4 4 125 460 3 4 0 3 15 13532 101 2 13766 032 5 S4T12500M5 4 125 575 3 4 0 3 15 13532 101 2 13766 032 5 S4T15000M4 4 150 460 3 4 0 3 15 13 13532 126 2 13766 032 5 S4T15000M5 4 150 575 3 4 0 3 15 13 13532 126 2 137...

Страница 13: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 14: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Страница 15: ......

Страница 16: ...oltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well T Yes T No Are Floats Set to Engineer s Specs T Yes T No Are Floats Wired for Proper Seq...