MEMBRANE INSTALLATION, REMOVAL AND REPLACEMENT
Installation and replacing membranes are an easy process if you have the proper information
at hand. Please refer to the following instructions when removing and replacing membrane
elements:
ALL PRESSURE GAUGES MUST READ ZERO BEFORE PROCEEDING.
BEFORE ATTEMPTING, DISCONNECT THE POWER FROM THE SYSTEM
AND BLEED ALL WATER PRESSURE FROM THE SYSTEM.
1) Perform this procedure one housing at a time to preserve the correct connections as
you replace the membranes (To remove Membrane 1, Carbon pre-filter must be
removed first).
2) Select the housing to be replaced.
3) Disconnect the fittings from the housing by simultaneously:
a) Pushing the grey collar toward the housing.
b) Pulling the tube from the collar.
4) Remove the screw from the clamp and twist the top clamp to un-hook the clamp.
5) Install new housing and re-connect tubing.
6) To start-up the system, please refer to the System Purging/Initial Start-Up (pages 15-
17)
section of this User’s Manual.
THE MEMBRANES MUST BE FLUSHED FOR AT LEAST 30 MINUTES.
DISCARD ALL OF THE PRODUCT (PURIFIED WATER) THAT IS PRODUCED
DURING THE FLUSH PERIOD.
Содержание Hydroid
Страница 1: ...Reverse Osmosis User Manual 888 426 5644 info hydrologicsystems com ...
Страница 2: ...Hydroid Series User Manual 2 04 19 This page intentionally left blank ...
Страница 24: ...Hydroid Series User Manual 24 04 19 OPERATING LOG ...
Страница 29: ...Hydroid Series User Manual 29 04 19 CIRCUIT BOARD LAYOUT ...
Страница 34: ...Hydroid Series User Manual 34 04 19 HYDROID FLOW DIAGRAM ...
Страница 35: ...Hydroid Series User Manual 35 04 19 ELECTRICAL SCHEMATIC ...
Страница 38: ...Hydroid Series User Manual 38 04 19 ...