HydroHoist Triton UltraLift Скачать руководство пользователя страница 5

 5

 

Set Boarding Height Timer 

allows you to lower the vessel to a set height off the water 

to load or unload your vessel while the lift holds the vessel from floating away

 

Important: This feature MUST be set or used from the fully raised position with ONLY 
the boat on the hoist. 

 

• 

Instructions to set Boarding Height Timer: Press 

LOWER 

and wait until the vessel 

reaches the desired boarding height. Once the desired boarding height is reached, 
press and hold 

LOWER 

button for 3 seconds. 

 

• 

Power LED will flash 

GREEN

 3 times indicating the boarding height timer is set. 

 

• 

To activate Boarding Height Mode:  Press and hold 

LOWER 

for 3 seconds. 

 

Remember, this feature MUST start from the fully raised position.

 The Power LED 

will turn solid 

BLUE 

indicating you are in Boarding Height Mode.  It will run the 

amount of time set from the above step and then return to 

STOP 

Mode. You can 

 

also press 

STOP

 at anytime to cancel boarding height.

 

 

Clear Boarding Height Timer

 

 Important: To set a new Boarding Height Timer you must first clear the old timer.

 

• 

Press and Hold the 

LOWER

 and 

STOP

 buttons together for 3 seconds

 

• 

Power LED will flash 

GREEN

 

3 times indicating it has been cleared   

 

 

 

 

Set Raise Timer 

allows you to set a less amount of time for 

RAISE MODE 

other than the 

default 10 minutes. 

Ideal feature for solar or battery option to save power 

 

Important: This feature MUST be set when the lift is completely lowered

 

• 

To set: Press 

RAISE

 then wait until the vessel is completely up and all tanks are 

 

bubbling and allow it to run an additional 30 seconds 

 

• 

Then Press and Hold the 

RAISE 

button for 3 seconds  

 

• 

Power LED will flash 3 times 

GREEN

 indicating the Raise Timer is set 

 

 

 Clear Raise Height Timer

 

 Important: To set a new Raise Height Timer you must first clear the old one 

 

• 

Press and Hold the 

RAISE

 and 

STOP

 buttons together for 3 seconds

 

• 

Power LED will flash 

GREEN

 3 times indicating the timer has been cleared   

 

Advanced Functionality of the Control

 

Содержание Triton UltraLift

Страница 1: ...Rev B 08062020...

Страница 2: ...of HydroHoist LLC is prohibited Any inquiries concerning HydroHoist LLC s published warranty or this manual and its contents should be referred to HydroHoist LLC 915 West Blue Starr Drive Claremore OK...

Страница 3: ...s 2 Press the RAISE button 3 Once the boat is fully raised and bubbles are exhausted from the tanks press the STOP button To Lower the Vessel 1 Press the LOWER button 2 2 You can press the STOP button...

Страница 4: ...essel Power LED is solid GREEN during this mode Lower mode will automatically shut off after 10 minutes if STOP is not pressed Stop Mode shuts all valves and verifies blower is off Power LED is solid...

Страница 5: ...n also press STOP at anytime to cancel boarding height Clear Boarding Height Timer Important To set a new Boarding Height Timer you must first clear the old timer Press and Hold the LOWER and STOP but...

Страница 6: ...ape 2 To open the valve manually pull the knob out 3 Start rotating the knob either direction Rotate 5 to 10 rotations until the valve is fully open As it starts to open you will start to hear the air...

Страница 7: ...7 Guide Rope Mooring Rope Solutions...

Страница 8: ...s manual and your hoist will give you years of trouble free service DO NOT s Do not push back excessively on the boat while the hoist is lifting Push back just enough to tighten the Guide Ropes and on...

Страница 9: ...9...

Отзывы: