background image

8

A

CTIVE

A

QUA

OPERATION

1.  Do NOT power on the Chiller unit yet. Fully submerge the water pump to be used, plug it in, 

and ensure that water is moving freely between the holding reservoir and the Chiller unit.

2.  Plug the Chiller into a grounded outlet and ensure the power switch located on the back 

of the unit is in the “ON” (I) position.

WARNINGS:

•  Do NOT cover the Chiller unit with anything during operation.
• Place the Chiller in the upright position ONLY for operation and storage purposes.
•  Avoid direct contact with liquids to the external body of the Chiller unit. Failure to do so 

may result in damage to the unit or electric shock.

•  Keep power cord free of obstructions, such as heavy or sharp objects sitting directly on it.
• This Chiller is approved for indoor use ONLY.
•  Keep the unit away from flammable vapors, direct sunlight, high temperature exposure, 

and high humidity.

•  Do NOT submerse the Chiller. Doing so will damage the unit and may inflict electric shock.

SETTING THE TEMPERATURE:

1.  Press and hold the SET button down for approximately 3 seconds to enter the water 

temperature programming mode. The previous water temperature setting will display.

2.  Use the /\ or \/ buttons on the control panel to increase or decrease the desired water 

temperature. Press the SET button once more, or wait approximately 8 seconds to select 

the desired temperature.

TEMPERATURE DISPLAY:

Press the SET button once to display the current set temperature value of the Chiller 

unit, press the SET button again to display the actual temperature value of the water. The 

blinking display indicates the set temperature.

TEMPERATURE ERROR ADJUSTMENT:

1.  When the reservoir water temperature differs from the set temperature value, an “II” 

indication should appear in the display.

2.  Press and hold the /\ and \/ buttons at the same time for approximately 6 seconds to enter 

the error adjustment programming mode. The display will blink once this status is active.

3.  By pressing either the /\ or \/ buttons, the error adjustment range can be mo/- 

1.5 degrees Celsius. *DO NOT USE THIS FUNCTION UNLESS IT IS NECESSARY*

Содержание ACTIVE AQUA AACH100

Страница 1: ...tem Reservoirs Ideal for ponic System Reservoirs AACH100 INSTRUCTION MANUAL Before operating this appliance please read this instruction manual thoroughly and keep on file for future reference 1HP 80 700GALLONS 300TO2500L ...

Страница 2: ...ONTENTS INTRODUCTION 3 SUGGESTIONS FOR SAFE OPERATION 3 FEATURES 4 TECHNICAL DATA 4 PERFORMANCE CURVE 5 INSTALLATION 6 ASSEMBLY 7 OPERATION 8 9 MAINTENANCE CLEANING 9 10 TROUBLESHOOTING 11 PARTS LIST 12 CIRCUIT DIAGRAM 13 GUARANTEE 14 ...

Страница 3: ... SUGGESTIONS FOR SAFE OPERATION Several symbols are used in this manual and on the product itself which are aimed at promoting proper and safe operation in order to prevent personal injuries or damage to the Chiller Please familiarize yourself with the symbols below before reading the manual or trying to operate the Chiller Terms And Symbols Hazard levels will be indicated in writing or shown by p...

Страница 4: ...rigeration Water Refrigerated 2000L 74 F 1 F Refrigerant R22 Refrigerant Weight 420 450g Rate of Flow 1500 4000L h Reservoir Capacity 80 700 GAL 300 2500L Weight 69 lbs Size 21 x 15 x 21 1 The rate of flow is decided according to the max jet of the pump immersible pump or other external power filter and the circulation equipment 2 The refrigeration performance test is indicated when the ambient te...

Страница 5: ... 88 F RESERVOIR CAPACITY 300L 2500L F PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 88 F 31 C THE WATER TEMPERATURE BEFORE REFRIGERATION IS 86 F 30 C AND THE WATER REFRIGERATED IS 500L 132 GAL 1000L 264 GAL AND 2000 L 528 GAL ...

Страница 6: ...ce Fig 4 5 Do not cover or move the Chiller while it is operating 6 The circulation water flow of the Chiller is indicated in the technology parameter table This Chiller does not have a water pump so it needs a pump with an available external filter Using a pump without an external filter may cause a water leak or other damage Fig 6 7 Do not put the Chiller on its side or upside down as this will ...

Страница 7: ...ired length of tubing onto each inflow and outflow fitting adapter with the worm drive hose clamps The inflow should connect the Chiller to the appropriate sized submersible water pump such as an ActiveAqua Water Pump in the proper sized reservoir see attached performance chart The outflow tube should hang freely in the reservoir to re introduce the chilled water back into the holding tank Please ...

Страница 8: ...may inflict electric shock SETTING THE TEMPERATURE 1 Press and hold the SET button down for approximately 3 seconds to enter the water temperature programming mode The previous water temperature setting will display 2 Use the or buttons on the control panel to increase or decrease the desired water temperature Press the SET button once more or wait approximately 8 seconds to select the desired tem...

Страница 9: ...posits and other debris may accumulate inside the Chiller reducing its effectivity see pg 10 Note Do NOT use soap or detergents for cleaning the internal components of the Chiller system 1 Disconnect the Chiller and submersible water pump from the power supply 2 Clean off the pump with a high powered hose or sprayer to remove debris and dirt from the pre filter and housing Clean the pre filter as ...

Страница 10: ... to the front WE RECOMMEND THE FOLLOWING AIR FILTER MAINTENANCE PROCEDURE ON A REGULAR BASIS 1 LOOSEN SCREW ON FRONT PANEL 2 GENTLY REMOVE FRONT PANEL 3 4 LOOSEN FILTER SCREWS AND REMOVE FILTER 5 LIFT AND REMOVE SIDE PANEL 6 7 LOOSEN SCREW ON SIDE PANEL AND REMOVE FILTER 8 REMOVE DUST WITH BRUSH VACUUM OR RINSE WELL WITH WATER DRY THOROUGHLY BEFORE REINSTALLING THE PARTS IN REVERSE ORDER ...

Страница 11: ...the water circulation is normal B If the fan and the Chiller dissipate heat normally wait for 3 minutes and the unit will automatically turn on again Fan is not working Return to place of purchase The set temperature is higher than the aquarium water temperature Reset temperature The air inlet or outlet are clogged Clean the air inlet outlet with a brush or a vacuum cleaner Not installed on a flat ...

Страница 12: ...e hose clamps 2ea c Rubber replacement collars extras 2ea 1 Front panel 2 Filter Front 3 Control command panel 4 Front cover 5 Circuit board 6 Back cover of circuit board 7 Bushing 8 Side filter 9 Side cover 10 Nut 11 Condenser 12 Back cover 13 Handle 14 Fan motor 15 Compressor 16 Base 17 Tank with evaporator 18 Top cover ...

Страница 13: ...tions so that the appropriate size pump may be implemented A pump that is either too weak or too powerful may impede the operation Vertical distance between the pump and the Chiller will affect the size of the pump that is needed I E If the pump only needs to project water 2 to get the Chiller unit compared to 10 a smaller pump can be used We recommend that the power source support ONLY the Chille...

Страница 14: ...w instructions is not covered If you have a problem recheck your system and pump If this does not remedy the situation contact the original place of purchase for a war ranty assessment Unauthorized returns will not be accepted Save your receipt invoice a copy is required for all warranty work Please contact your place of purchase for warranty information 1 1 on reflective materials ...

Страница 15: ......

Страница 16: ...Made In China To Hydrofarm s Exacting Specifications Distributed By Hydrofarm Inc Petaluma CA www hydrofarm com ...

Отзывы: