background image

INSTRUCTION MANUAL

Hydrofarm.com

2

Thank you for purchasing the Active Air Inline Duct Fan. Active Air Inline Duct Fans offer 

innovation and performance at a great price.

4.0

3.6

3.2

2.8

2.4

2.0

1.6

1.2

0.8

0.4

0.0

1000

900

800

700

600

500

400

300

200

100

0

[P

a]

[in H

2

O]

0  120 240 360 480 600 720 840 960 1080 

1200 [CFM]

0  160 320 480 640  80  960 1120 1280 

1440 

1600 

[m

3

/h]

Sta

tic P

ressur

e

Air Flow

Voltage

  120AC/60Hz  10µf/250V

AIR FLOW

ACDF42

4.0

3.6

3.2

2.8

2.4

2.0

1.6

1.2

0.8

0.4

0.0

1000

900

800

700

600

500

400

300

200

100

0

[P

a]

[in H

2

O]

0  120 240 360 480 600 720 840 960 1080 

1200 [CFM]

0  160 320 480 640  80  960 1120 1280 

1440 

1600 

[m

3

/h]

Sta

tic P

ressur

e

Air Flow

Voltage

  120AC/60Hz  10µf/250V

AIR FLOW

ACDF6

4.0

3.6

3.2

2.8

2.4

2.0

1.6

1.2

0.8

0.4

0.0

1000

900

800

700

600

500

400

300

200

100

0

[P

a]

[in H

2

O]

0  120 240 360 480 600 720 840 960 1080 

1200 [CFM]

0  160 320 480 640  80  960 1120 1280 

1440 

1600 

[m

3

/h]

Sta

tic P

ressur

e

Air Flow

Voltage

  120AC/60Hz  20uf/450V

Voltage

  120AC/60Hz  15µf/250V

AIR FLOW

ACDF8

4.0

3.6

3.2

2.8

2.4

2.0

1.6

1.2

0.8

0.4

0.0

1000

900

800

700

600

500

400

300

200

100

0

[P

a]

[in H

2

O]

0  120 240 360 480 600 720 840 960 1080 

1200 [CFM]

0  160 320 480 640  80  960 1120 1280 

1440 

1600 

[m

3

/h]

Sta

tic P

ressur

e

Air Flow

Voltage

  120AC/60Hz  20µf/250V

AIR FLOW

ACDF10

4.0

3.6

3.2

2.8

2.4

2.0

1.6

1.2

0.8

0.4

0.0

1000

900

800

700

600

500

400

300

200

100

0

[P

a]

[in H

2

O]

0  120 240 360 480 600 720 840 960 1080 

1200 [CFM]

0  160 320 480 640  80  960 1120 1280 

1440 

1600 

[m

3

/h]

Sta

tic P

ressur

e

Air Flow

Voltage

  120AC/60Hz  20µf/250V

AIR FLOW

ACDF12

WHAT’S IN THE BOX

After unpacking the box, please 

confirm that all of the following parts 

are included.

• 

Active Air Inline Fan with 8' 

 

pre-wired 120V cord

• 

Mounting Brackets

• 

Screws

SPECIFICATIONS

MODEL Dia. CFM

Rated 

Amperage

Rated 

Wattage

RPM

ACDF12

12"

969

2.5A

300W

2573

ACDF10

10" 760

2.07A

236W

2480

ACDF8

8"

720

1.76A

210W

2530

ACDF6

6"

400

0.97A

115W

2911

ACDF42

4"

188

0.62A

74W

2850

AIR FLOW RATES

Содержание Active Air ACDF10

Страница 1: ...INSTRUCTION MANUAL ACDF12 INLINE DUCT FANS ACDF10 ACDF8 ACDF6 ACDF42 MODE D EMPLOI 5 INSTRUCCIONES 8 ...

Страница 2: ... 640 80 960 1120 1280 1440 1600 m3 h Static Pressure Air Flow Voltage 120AC 60Hz 20uf 450V Voltage 120AC 60Hz 15µf 250V AIR FLOW ACDF8 4 0 3 6 3 2 2 8 2 4 2 0 1 6 1 2 0 8 0 4 0 0 1000 900 800 700 600 500 400 300 200 100 0 Pa in H 2 O 0 120 240 360 480 600 720 840 960 1080 1200 CFM 0 160 320 480 640 80 960 1120 1280 1440 1600 m3 h Static Pressure Air Flow Voltage 120AC 60Hz 20µf 250V AIR FLOW ACDF1...

Страница 3: ...y carry out maintenance after the electrical supply has been isolated Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer or place of purchase Active Air inline duct fans are designed for use in up to 95 relative humidity They are not humidifiers or dehumidifiers This fan is not suitable for corrosive or explosive atmospheres Installation wo...

Страница 4: ...ead to permanent damage to the fan motor 5 Refer to the appropriate wiring diagram and ensure that all ground connections are made 6 You must incorporate means for electrical disconnection in the wiring installation in accordance with the relevant wiring and electrical regulations MAINTENANCE All Active Air inline duct fans incorporate sealed for life bearings and therefore do not require any lubr...

Страница 5: ...O 0 120 240 360 480 600 720 840 960 1080 1200 CFM 0 160 320 480 640 80 960 1120 1280 1440 1600 m3 h Static Pressure Air Flow Voltage 120AC 60Hz 10µf 250V AIR FLOW ACDF6 4 0 3 6 3 2 2 8 2 4 2 0 1 6 1 2 0 8 0 4 0 0 1000 900 800 700 600 500 400 300 200 100 0 Pa in H 2 O 0 120 240 360 480 600 720 840 960 1080 1200 CFM 0 160 320 480 640 80 960 1120 1280 1440 1600 m3 h Static Pressure Air Flow Voltage 1...

Страница 6: ...limentation électrique Utiliser cet appareil uniquement de la manière prévue par le fabricant En cas de doute contactez le fabriquant ou le vendeur Les ventilateurs de conduit en ligne d Active Air sont conçus pour être utilisés dans des lieux dont l humidité relative est de 95 Ce ne sont pas des humidificateurs ni des déshumidificateurs Le ventilateur n est pas approprié pour être utilisé dans de...

Страница 7: ...rsibles sur le moteur du ventilateur 5 Consultez le schéma du câblage approprié et assurez vous d avoir réalisé tous les branchements à la terre 6 Il faut prévoir des moyens pour le débranchement électrique dans l installation du câblage selon les normes électriques et de câblage en vigueur MAINTENANCE Tous les ventilateurs en ligne Active Air comportent des roulements étanches à vie et ne nécessi...

Страница 8: ...60 480 600 720 840 960 1080 1200 CFM 0 160 320 480 640 80 960 1120 1280 1440 1600 m3 h Static Pressure Air Flow Voltage 120AC 60Hz 10µf 250V AIR FLOW ACDF6 4 0 3 6 3 2 2 8 2 4 2 0 1 6 1 2 0 8 0 4 0 0 1000 900 800 700 600 500 400 300 200 100 0 Pa in H 2 O 0 120 240 360 480 600 720 840 960 1080 1200 CFM 0 160 320 480 640 80 960 1120 1280 1440 1600 m3 h Static Pressure Air Flow Voltage 120AC 60Hz 20u...

Страница 9: ... el suministro eléctrico Utilice esta unidad únicamente de la forma prevista por el fabricante En caso de que tenga cualquier duda póngase en contacto con el fabricante o con el punto de venta Los ventiladores en línea para conductos Active Air están diseñados para usarse en ambientes con una humedad relativa de hasta un 95 No son humidificadores ni deshumidificadores Este ventilador no es adecuad...

Страница 10: ...cuado puede causar daños permanentes en el motor del ventilador 5 Consulte el diagrama de cableado y asegúrese de la presencia de todas las tomas de tierra 6 Debe incorporar medios para la desconexión eléctrica en la instalación del cableado según las normativas de cableado y eléctricas pertinentes MANTENIMIENTO Todos los ventiladores en línea para conductos Active Air incorporan rodamientos sella...

Страница 11: ... THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Страница 12: ...ate d achat Cette garantie ne couvre pas l utilisation incorrecte l abus ou le non respect de la notice Hydrofarm selon ses critères réparera ou remplacera Active Air Inline Duct Fan couvert par cette garantie s il est renvoyé au centre original d achat Pour demander le service de garantie renvoyer Active Air Inline Duct Fan avec le ticket d achat et l emballage originaux au centre d achat La date...