HydroCheck HC6000v2 Скачать руководство пользователя страница 2

How the Sensors Work: Do I need a ground wire? 

The sensors detect the presence of water by using a continuity circuit. The continuity circuit works by allowing a very small current 

to flow from each the sensor, through the water, to ground when the tip of the sensor is in water. When no water is present, the 

circuit is broken and no current flows. Normally, the pump provides the ground reference needed for the continuity circuit to work, 

but occasionally it won’t. A 

Flashing LED and audible alarm indicates a weak ground reference

. When this happens, it is nec-

essary to provide a ground reference for the sensor to work. 

Adding a Ground Wire: 

TROUBLESHOOTING: 

Alarm & LED Guide 

Smart Button Features

 

WARRANTY: 

STAK Enterprises Inc. warrants the model

 HC6000v2 

to be free from defects in materials and workmanship for its normal, useful life, for a period of 5 

years from the date of purchase.  STAK Enterprises Inc. makes no other express warranty for this device.  No agent, representative, dealer, or employee 
of STAK Enterprises Inc. has the authority to increase or alter the obligations or limitations of the warranty. The company's obligation of this warranty 
shall be limited to the repair or replacement of any part of the HC6000v2 which is found to be defective in materials or workmanship under normal use 
and service during the 5 year period of product use by original product owner commencing with the date of purchase.  Owner must pay all shipping 
charges necessary to replace product covered by this warranty.  This warranty shall not apply to acts of God, nor shall it apply to products which, in the 
sole judgment of STAK Enterprises, Inc. have been subject to negligence, abuse, accident, tampering, alteration, misapplication, or improper installation. 

THE DURATION OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING THAT OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR 
PURPOSES, SHALL BE LIMITED TO THE NORMAL, USEFUL LIFE OF THE PRODUCT, COMMENCING WITH THE DATE OF PURCHASE.  IN NO 
CASE SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER 
WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER.

Step 1

Strip 1 inch of insulation off each end of a 14 AWG length of wire.

Step 2

Secure one end of the wire to a copper water pipe or metal electrical conduit.

Step 3

Place the other end of the wire into the pit so that it is 

below

 the Lo-Sensor. 

NOTE:

 No danger of electrocution. Visit our website www.hydrocheckproducts.com for more information.

Meaning

Possible Cause

Red LED

The switch's output is off (the pump is off).

None—Normal operation

Green LED

The pump is on and water is above the lo-sensor.

None—Normal operation

Flashing LED and Fixed 

Rate Alarm 

(Green or Red)

Weak or missing ground reference detected during a 

cycle.

See 

How the Sensors Work: Do I need a 

ground wire?

 above.

2-Beep Alarm 

(No Pump Current 

Detected)

The switch did not detect a motor current during the 

previous pumping cycle.

• Pump is not plugged in 

• Pump failure 

• Mechanical float switch is not disabled

3-Beep Alarm 

(High Water Alarm)

High Water Alarm will sound if water does not drop 

below the Hi-Sensor within 25 seconds following two 

anti-airlock cycles. 

NOTE:

 See the Product FAQ page on our website for 

more information about airlock cycles 

www.hydrocheckproducts.com

• Pump failure 

• Pump can’t keep up 

• Blocked or frozen discharge pipe 

• Trapped air is preventing normal pump 

operation (airlock)

Goal

Method

Silence Alarm

Pressing and releasing the Smart Button while an alarm is active will silence the alarm for 24hrs.

Disable Alarm

Pressing and holding the Smart Button while an alarm is active will disable the alarm until the switch is 
reset. The Smart Button should be pressed and held until the device sounds a short beep followed by a 
long beep, indicating that the alarm was successfully disabled. 

Switch Reset

Press and hold Smart Button while plugging switch into a 120 VAC outlet. A short beep will sound to 
indicate that the switch has been reset. Resetting the switch returns all settings back to the original fac-
tory defaults.

Manually Run Pump

Press and hold the Smart Button while the LED is solid red. The pump will run until the button is re-

leased.

Cancel Cycle

Press and release the Smart Button while the pump is on to cancel the cycle.

 

 

www.hydrocheckproducts.com | [email protected] | 1(877)-225-2124

2

Rev-A

Отзывы: