HC6000v2 Electronic Sump Pump Switch

  

Overview: 

The HydroCheck 

HC6000v2 Electronic Sump Pump Float Switch with Hi-Lo Dual Sensors and Built-in Alarms 

is a universal 

float switch that works with all types of sump pumps. The pump cycle will start when water reaches the Hi-Sensor (Red) and stop 
when water drops below the Lo-Sensor (Black). Easily achieve your desired cycle length by adjusting the distance between the 
sensors. See the Troubleshooting section for Smart Button, LED and Alarm specifications. Not rated for outdoor use.

 

READ PRIOR TO INSTALLATION: 

1.

The 

“piggyback plug”

 attached to the mechanical float switch 

cannot be used with the HC6000v2

It must be dis-

connected and remain disconnected. 

2.

If your sump pump has 

internal float switch wiring

, i.e. does not have a “piggyback plug”, then you 

must

 secure 

the float in an 

upward position

 as if the pit were full. This assures that the internal switch is always closed and that 

the pump is enabled. 

3.

Pits that receive water from a water softener or that have 

high mineral/iron content

 require an

 alternative installa-

tion method

. Use the HydroCheck 

Sensor Installation Kit

 to ensure maximum reliability in all installation ap-

plications. Visit our website 

www.hydrocheckproducts.com 

for more information. 

  

Step-by-Step Installation 

Step 1

Unplug the sump pump from the back of the “piggy-

back plug”.

Step 2

Unplug the “piggyback plug” from the 120 VAC and 

set aside. The HC6000v2 completely replaces this 

component.

Step 3

Secure the 

red sensor

 (A) to the 

discharge pipe

 (B) 

with 

tie wrap

 (C) where the pump is intended to turn 

on. 

NOTE:

 Recommended height for the Red Sensor is 

slightly below the Drain Tile (Water Inlet Pipe). 

Step 4

Secure the 

black sensor

 (D) to the 

discharge pipe 

(B) with 

tie wrap

 (C) where the pump is intended to 

turn off. 

Step 5

Check that the 

red sensor

 (A) is positioned 

above

 

the 

black sensor

 (D).

Step 6

Plug the 

control module

 (E) into a 3-prong 120 VAC 

outlet.  

NOTE:

 The output will turn on briefly and the LED will 

illuminate red. If the Red Sensor detects water, a 
pump cycle will begin. 

Step 7

Plug the sump 

pump power cord

 (F) into the

 con-

trol module

 (E).  

NOTE: 

The HC6000v2’s output is rated for a maxi-

mum of 1 HP and/or 15 amps at 120 VAC. 

Step 8

TEST YOUR INSTALLATION BEFORE LEAVING IT 
FOR UNATTENDED USE. 

NOTE: 

This product 

will not work if tested in a cup 

of water.

 See 

How the Sensor Works: Do I need a 

ground wire?

 On Page 2 for more information.

 

 

www.hydrocheckproducts.com | [email protected] | 1(877)-225-2124

1

Rev-A

with Hi-Lo Dual Sensors and Built-in Alarms

A. Red Sensor (Hi-Sensor) D. Black Sensor (Lo-Sensor)

B. Discharge Pipe

E. Control Module

C. Tie Wrap

F. Pump Power Cord

*“Piggyback plug” and 120 VAC outlet are not pictured

Installation Key

Product Dimensions

2.8 x 2.5 x 3.5 in

Weight

14.4 oz

Output Rating

120 VAC, 15 Amp, 1 HP

Alarm Rating

80 dB

Power

120 VAC, 60 Hz

Sensor Cable Length

12 ft

Anti-Airlock Cycle

2 Attempts

Product Specifications