background image

- 3 - 

O2 Hydro SM 
20170222 

 
 

 

 

 

Connection Instructions 

 

 

1.

 

Installation must comply with any existing state or local plumbing codes. 

2.

 

Turn off your water supply.  Turn off power to well.  Turn off your water heater. 

3.

 

Release water pressure by opening a nearby faucet. 

4.

 

Attach water source to the male adapter on the 

inlet

 side of the by-pass valve. If existing inlet pipe size is smaller 

or greater than 1”, you will need an additional adapter.  

5.

 

Attach the outgoing water line to the male adapter on the

 outlet

 of the Bypass. 

6.

 

Connect to the filter housing provided. Recommend a shut off valve be installed for future filter changes. The 

outlet side of the filter housing is connected to the water line in to the house.   

7.

 

Turn Bypass valve with the arrow pointing to “

SERVICE

” 

(Figure 4)  

8.

 

Turn on the power to the well then turn on  hot water heater.   

9.

 

Plug in Main Control Head into wall outlet.  Use the Surge Protector.  

10.

 

Set time of day on Main Control Head.  Refer to 

PAGE 4

 of Owner’s Manual for instructions.   

11.

 

Turn

 

your water on to allow water to slowly fill the volume in the Media Tank.

  

12.

 

After tank is full  press the 

Extra Cycle

 button on the Main Control Head and hold for 5 seconds to enter “BACK-

WASH”. You will see water appear in the drain line  

13.

 

Continue to backwash the media until the water in the drain line runs clear. This can take (60) minutes or more.  

 

Troubleshooting Guide 

■ If water leaks at fittings:  Tighten slightly more until leak stops. 
 

 Note: This tank has an easy service port on the top that will allow you if needed, to add regeneration material 

to the media that can help solve service issues if they arise.  

 

 

Note:   Fill out the enclosed Warranty Card and mail. Manufacturer Warranty is 5 years on parts. Your serial number is located 

on the underside of the Main Control Head. Make appropriate entries on the Maintenance Card provided (ie. date installed and 

dates medias are changed). Keep attached to the system and update when needed. 

The HydroCare Service Department can be reached Monday – Friday, from 9am – 4pm PST at 888-963-6178 or at 

 

www.hqhometek.com/solutions/water-solutions

.   

 