ELECTRONIC CONTROL BOX, 1 FUNCTION 20-0241 

 

Specifications 

Rated voltage: 

 

230 V, 50/60 Hz, single phase 

Rated power: 

 

3680 W  

Rated current: 

 

16 A 

The total sum of the loads must not exceed the rated power and current.  
 

Dimensions & temperatures 

Weight: 

 

  0.5 

kg 

     

Length:     160 

mm  

Width:    80 

mm

 

 

Depth:     60 

mm 

 
Operating temperature:  0 to 50°C 
Storage temperature: 

-20 to 50°C 

 

Important 

This control box is not suitable for medical use. Follow the directions for installation and connection. We reserve 
the right to change the product and the specification without notice.  
 

Safety rules 

A. 

Locate the box in a dry area with good ventilation. 

B. 

The box must be situated at least 3 cm above the ground floor. 

C. 

Before cleaning, servicing, exchanging of parts or accessories or checking up on various disturbances, the 
mains have to be cut off. 

D. 

Make sure that there are no unconnected wires and cables inside the box. 

E. 

Cables and wires must be as short as possible inside and outside the box. 

F. 

The box is protection Class I. It has to be connected with cables according to the instructions from EN 
60335-1 and EN 60335-2-60. It is recommended that you consult a state registered electrician. The supply 
cable has to be minimum type H05VV-F; 3G1.5 mm

2

G. 

Keep at all time minimum 20 mm distance between high and low power cables. 

H. 

In order to separate the box from the mains you must install a suitable ground fault circuit interrupter with at 
least 3 mm break distance on each terminal in the present electrical installation. 

I. 

The mounting is to be made in such a way that it is not possible to touch the electric parts. 

J. 

The electric parts have to be mounted in such a way that they cannot fall into the bathtub. 

K. 

Instruments of Class I must be connected to a permanent installation. 

L. 

Be aware that some countries have requirements about power indication. 

M. 

Tighten all cable glands sufficient by means of a tool to ensure that the Ingres protection is IPX5 and to 
ensure that the cables are fixed in position and protected for physical traction and pressure. 

N. 

If not all cable outlets are used, the cable gland(s) in question has to be changed to dummy plug(s) of the 
same dimension to ensure that the Ingres Protection still is IPX5. 

O. 

This appliance is not intended for use by persons, including children with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision or in-
struction concerning use of the appliance by a responsible for their safety. 

P. 

Children should be supervised to ensure that they do not play with the appliance.  

 

How to mount cable onto cable gland 

1. Pull the cable through A. 
2. Pull the cable through B and C (B is    
    normally placed inside C). 
3. Tighten A sufficient onto C by means of a  
    tool. 
4. Mount the spade- and eye shoes onto  
    wire ends where this is necessary. 

 
 

 
 

49-20-0241, 

www.hydroair.dk

, June 2010 

 
 

1/8 

Содержание 20-0241

Страница 1: ... mains you must install a suitable ground fault circuit interrupter with at least 3 mm break distance on each terminal in the present electrical installation I The mounting is to be made in such a way that it is not possible to touch the electric parts J The electric parts have to be mounted in such a way that they cannot fall into the bathtub K Instruments of Class I must be connected to a perman...

Страница 2: ...ter filling is started by pressing the touch The solenoid valve normally closed will open for water flow Diode indicates the function is active When water level reaches the water level sensor water filling will stop automati cally It is recommended to set jumper X2 in ON position which activates a 30 minutes timer This is a security option to prevent waste of water in case of a failure on the wate...

Страница 3: ...r FI Schalter zu installieren der mindestens 3 mm Abstand zu jedem Anschlusselement der bestehenden Elektroinstallation hat I Die Montage muss so erfolgen dass es nicht möglich ist mit elektrischen Bauteilen in Berührung zu kommen J Die Elektronischen Bauteile müssen so montiert werden dass sie keinesfalls in die Wanne fallen können K Geräte der Klasse I müssen an eine dauerhafte Installation ange...

Страница 4: ...der Taste beginnt die Wasserbefüllung Das Rückschlagventil normalerweise geschlossen wird für den Wasserzufluss geöffnet was durch eine Leuchtdiode angezeigt wird Die Wasserbefüllung stoppt automatisch wenn der Wasserstand den Wasserstandssensor erreicht Es ist empfehlenswert den Jumper X2 auf ON zu stellen um die 30 Minuten Zeitschaltuhr zu aktivieren Dies ist eine Sicherheitsmaßnahme um im Falle...

Страница 5: ...ecteur vous devez installer un disjoncteur de fuite à la terre approprié avec une distance disruptive minimale de 3 mm sur chaque borne dans l installation électrique actuelle I Le montage doit être effectué de manière à éviter tout contact avec les composants électriques J Les composants électriques doivent être montés de manière à ce qu ils ne puissent pas tomber dans la baignoire K Les instrume...

Страница 6: ...le bouton L électrovanne normalement fermée s ouvre pour laisser passer l eau Une diode indique que la fonction est active Lorsque le niveau d eau atteint la sonde le remplissage d eau cesse automatiquement Il est recommandé de régler le cavalier X2 sur la position ON pour activer une minuterie de 30 minutes Cette option de sécurité empêche tout gaspillage d eau en cas de panne de la sonde de nive...

Страница 7: ...m minimum være type H05VV F 3G1 5 mm2 G Der skal være en afstand på mindst 20 mm mellem stærk og svagstrømskabler H Boksen skal adskilles fra nettet af en kontakt med en brydeafstand på min 3 mm på hver pol I Installeringen skal foretages således at det ikke er muligt for brugeren at berøre elførende dele J Alle elektriske dele skal være således monteret at der ikke er mulighed for at disse kan fa...

Страница 8: ...dningstavlen aktiveres på 1 funktionstouchen hvorved magnetventilen åbner for vandpåfyldning Dio den lyser ved tændt Når vandniveauet når til vandstandssensoren lukker vandpåfyldningstavlen automatisk for vandtilførslen Det anbefales at stille jumper X2 i ON position hvilket tillader vandpåfyldning i maks 30 min Dette som sikkerhed for at begrænse vandspild ved evt driftssvigt på vandstandssensore...

Отзывы: