Hydro FM-800 Flush Manifold Скачать руководство пользователя страница 4

troubleshooting and maintenance

HYD10098686XT  Rev A  09/19

Hydro Systems

3798 Round Bottom Road

Cincinnati, OH 45244

Phone

  

513.271.88OO

 

Toll Free

  

8OO.543.7184 

Fax

  

513.271.O16O

Web

  

hydrosystemsco.com

Problem

Cause

Solution

1. Pump will not run  

There are various potential causes for this problem.  Please follow the steps below to diagnose and address the problem:
a. Is water supply on?  If not, turn on water supply.  If yes continue to step b.
b. Disconnect flush manifold wire harness from the pump stand and install the flush jumper that came with the pump stand. 
c. Using the prime pump function of the controller, run one of the pumps.  
d. If the pump runs, go to step e.  If pump does not run, STOP troubleshooting, call Hydro Systems Technical Support for help.
e. Measure your water flow by following the steps below:
    1) Turn off the incoming water supply.
    2) Disconnect the brass water inlet fitting from the push-fit connector on the flow switch  
    3) Get an empty one gallon container.  
    4) Turn on water supply.
    5) Capture the incoming water flow with the one gallon container and time how long it takes to fill the one gallon container.
    6) If it fills in one minute or less, so your flow rate is at least 1 gallon per minute, proceed to step f.
    7) If the incoming water flow is less than 1 gallon per minute, STOP and check your water supply.  
       (Water supply flow must be at least 1 gallon per minute for the Flush Manifold’s flow switch to activate.)
f.  Reconnect the brass water inlet and supply hose to the push-fit connector on the Flush Manifold. 
g. Reconnect the flush manifold wire harness to the pump stand. 
h. Check that discharge hose to the washer is free of kinks.
i.  Disconnect discharge hose at the washing machine inlet.
j.  Aim discharge hose to floor drain and activate a pump using the prime feature.
    If the pump runs, there is blockage at inlet fitting.  If pump does not run proceed to step k.
k. Turn on a pump with the prime function and collect the fluid coming out the discharge hose in a one gallon container.
    If the output is less 1 gallon per minute, proceed to step l.  If the output is 1 gallon per minute or more, call Hydro Systems 
    Technical Support for assistance. 
l.  Activate a pump with the prime function and check voltage at the coil of the Flush Manifold solenoid valve.
   If you measure 24 v     and there is no flow at the manifold outlet, replace the solenoid valve. 
   If you do not measure 24 v     on the coil of the solenoid with a pump active, call Hydro Systems Technical Support for help.

2. Water in chemical line, 
    between pump and flush
    manifold

a. Chemical check valve 
    defective or clogged

Replace check valve.

3. Water drips/runs into the
    washer at all times

a. Defective solenoid valve Rebuild or replace the solenoid valve.

4. Water leaks out of vent
    check valve

a. Defective or clogged 
    vent check valve

A small amount of water may periodically leak from the vent check valve in normal operation. You can 
attach a short length of tubing to the barb to capture the fluid.  If you still see a significant amount of 
water exiting the vent and tubing, the check valve has probably failed. Replace the vent check valve.

WARNING!

 

Under no circumstances should the flow switch be by-passed by jumping wires. The flow switch is a safety feature that if by-

passed will void the warranty of the Flush Manifold and Hydro Systems will not assume any responsibility for the mixing of chemicals in the manifold!

Limited Warranty

Seller

 warrants solely to 

Buyer

 the Products will be free from defects in material and workmanship under normal use and 

service for a period of one year from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; 

(b) and products that have a normal life shorter than one year; or (c) failure in performance or damage caused by chemicals, 

abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event 

the Products are altered or repaired by 

Buyer

 without 

Seller’s

 prior written approval, all warranties will be void.

No other warranty, oral, express or implied, including any warranty of merchantability or fitness for any particular 

purpose, is made for these products, and all other warranties are hereby expressly excluded.

Seller’s

 sole obligation under this warranty will be, at 

Seller’s

 option, to repair or replace F.O.B.

 Seller’s

 facility in Cincinnati, 

Ohio any Products found to be other than as warranted.

Limitation of Liability

Seller’s

 warranty obligations and 

Buyer’s

 remedies are solely and exclusively as stated herein. 

Seller 

shall have no other 

liability, direct or indirect, of any kind, including liability for special, incidental, or consequential damages or for any other claims 

for damage or loss resulting from any cause whatsoever, whether based on negligence, strict liability, breach of contract or 

breach of warranty.

Содержание FM-800 Flush Manifold

Страница 1: ...ers Regularly inspect equipment and keep equipment clean and properly maintained Use a locally approved back flow prevention device not provided as required for safe legal operation Mix incompatible chemicals that pose hazards Only to water tap outlets at 0 2 MPa 1 7 Bar 25 PSI Min 0 6 MPa 6 Bar 85 PSI Max and maximum water temperature 60 C 140 F Operating outside of these parameters will void man...

Страница 2: ...d the washing machine 8 Avoid kinks and other restrictions in discharge tube Dynamic manifold pressure that exceeds 0 2 MPa 2 Bar 30 PSI during operation can severely reduce pump and squeeze tube life This condition may also cause excessive back pressure in the squeeze tubes resulting in potential dispensing equipment damage and or personal safety risks IMPORTANT NOTE Water inlet fitting size is 1...

Страница 3: ...00 LM 200 Electrolux SDS and LL 6000 systems utilizes 24v for the water solenoid valve If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard NOTE To manually open the flush valve to purge or clean water lines and manifold use the Prime Pumps function of the controller If no product delivery is desired use a...

Страница 4: ... the manifold outlet replace the solenoid valve If you do not measure 24 v on the coil of the solenoid with a pump active call Hydro Systems Technical Support for help 2 Water in chemical line between pump and flush manifold a Chemical check valve defective or clogged Replace check valve 3 Water drips runs into the washer at all times a Defective solenoid valve Rebuild or replace the solenoid valv...