Hydro FM-800 Flush Manifold Скачать руководство пользователя страница 1

  

  FM-800 Flush Manifold Assembly 

w/Brackets (P/N varies by model)

  

  Hardware Kit

  

  3/8” Braided Tubing (A 2-foot 

section for each port)

user manual

FM-8OO Flush Manifold

Package Contents

introduction

           

Safety Precautions

            

WARNING! 

 

P

lease read these warnings carefully and follow all applicable local codes and regulations.

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS!

TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE:

P

rotective clothing and eyewear when dispensing chemicals or other materials, when working in the vicinity

of chemicals, and when filling or emptying equipment.

R

ead and follow all safety instructions in safety data sheets (SDS) for all chemicals.

O

bserve all safety and handling instructions of chemical manufacturer.

D

ilute and dispense chemicals in accordance with chemical manufacturer‘s instructions.

D

irect discharge away from you and other persons and into approved containers.

R

egularly inspect equipment and keep equipment clean and properly maintained.

U

se a locally approved back-flow prevention device - not provided - as required for safe, legal operation.

M

ix incompatible chemicals that pose hazards.

O

nly to water tap outlets at 0.2 MPa / 1.7 Bar / 25 PSI Min., 0.6 MPa / 6 Bar / 85 PSI Max. and maximum 

water temperature 60°C / 140°F. Operating outside of these parameters will void manufacturer’s warranty

I

t is recommended to flush with a dedicated COLD water supply only, when possible.

WEAR

NOTE

ALWAYS

NEVER

ATTACH

chemical ports with check valves

connection to pump stand

inline check valve

solenoid

water

valve 

flow

switch

discharge

to laundry

water

inlet

inlet

support

wall

hangers

vent

port

manifold

swivel

Model Numbers

Description

Chemical Port

Barb Size

Discharge

Barb Size

HYD00-03608-02XT FM-800, 2 Product Flush Manifold

3/8”

1/2”

HYD00-03608-04XT FM-800, 4 Product Flush Manifold

3/8”

1/2”

HYD00-03608-06XT FM-800, 6 Product Flush Manifold

3/8”

1/2”

HYD00-03608-08XT FM-800, 8 Product Flush Manifold

3/8”

1/2”

HYD00-03608-01XT FM-800, 2 Product Add-on Kit

3/8”

1/2”

Содержание FM-800 Flush Manifold

Страница 1: ...ers Regularly inspect equipment and keep equipment clean and properly maintained Use a locally approved back flow prevention device not provided as required for safe legal operation Mix incompatible chemicals that pose hazards Only to water tap outlets at 0 2 MPa 1 7 Bar 25 PSI Min 0 6 MPa 6 Bar 85 PSI Max and maximum water temperature 60 C 140 F Operating outside of these parameters will void man...

Страница 2: ...d the washing machine 8 Avoid kinks and other restrictions in discharge tube Dynamic manifold pressure that exceeds 0 2 MPa 2 Bar 30 PSI during operation can severely reduce pump and squeeze tube life This condition may also cause excessive back pressure in the squeeze tubes resulting in potential dispensing equipment damage and or personal safety risks IMPORTANT NOTE Water inlet fitting size is 1...

Страница 3: ...00 LM 200 Electrolux SDS and LL 6000 systems utilizes 24v for the water solenoid valve If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard NOTE To manually open the flush valve to purge or clean water lines and manifold use the Prime Pumps function of the controller If no product delivery is desired use a...

Страница 4: ... the manifold outlet replace the solenoid valve If you do not measure 24 v on the coil of the solenoid with a pump active call Hydro Systems Technical Support for help 2 Water in chemical line between pump and flush manifold a Chemical check valve defective or clogged Replace check valve 3 Water drips runs into the washer at all times a Defective solenoid valve Rebuild or replace the solenoid valv...

Отзывы: