PARTS LIST (Refer to diagram)
Key # Part Number
Description
1
238100
Strainer washer
2
2767-K
Swivel connector assembly
3
133000
Branch tee
4
10030500
3.8" Nipple
5
10041701
Clamp
6
10075925
Pipe plug
7
10084080
Ball valve
8
10082951
Tubing
9
10082900
Compression fitting
a
10082905
Body
b
10082906
Nut
c
10082901
Tubing sleeve
10
10005803
Nut
11
10084051
Cover
12
605400
Hose hanger
13
328900
Hose connector adapter
14
90032500
Tee
15
10084701
Hex nipple
Key # Part Number
Description
16
90032510
Discharge elbow
17
276800
Stem, short
18
506502
Swivel nut
270700
Washer
19
10069270
Check valve, Viton*
20
440800
3.5 GPM eductor
21
10067810
Nipple
22
10027209
Metering tip (kit)
23
500870
Suction tube, 1/4" x 7'
24
509900
Weight
25
609600
Strainer
NOT SHOWN:
10072711
Mounting hardware kit
* EPDM check valve available: order 10069271
HydroChem Parts Diagram
APPROXIMATE DILUTIONS
AT 40 PSI FOR WATER-THIN PRODUCTS (1.0 CP)
Orifice
Std. Drill
Size
Number)
Ratio
Tip Color
CONVERSION CHART:
Ratio Equivalents to
Standard Measures
Oz./Gal.
Ratio
%
No Tip
.187
(3/16)
10:1
128
1:1
50.0
Gray
.128
(30)
10:1
64
2:1
33.3
Black
.098
(40)
10:1
32
4:1
20.0
Beige
.070
(50)
12:1
21
6:1
14.3
Red
.052
(55)
16:1
16
8:1
11.1
White
.043
(57)
24:1
14
9:1
10.0
Blue
.040
(60)
28:1
8
16:1
5.9
Tan
.035
(65)
32:1
6
24:1
4.0
Green
.028
(70)
48:1
4
32:1
3.0
Orange
.025
(72)
64:1
3
48:1
2.0
Brown
.023
(74)
80:1
2
64:1
1.5
Yellow
.020
(76)
96:1
1
128:1
0.8
Aqua
.018
(77)
128:1
1/2
256:1
0.4
Purple
.014
(79)
256:1
1/4
512:1
0.2
Pink
.010
(87)
284:1
Lt. Purple
.009
(89)
512:1
Measurement of Concentration:
You can determine the dispensed water-to-product ratio for any metering tip size and product viscosity. All that
is required is to operate the primed dispenser for a minute or so and note two things: the amount of dispensed
water/product mixture, and the amount of concentrate used in preparation of the solution dispensed. The
water-to-product ratio is then calculated as follows:
Dilution (X) = Amount of Mixed Solution -- Amount of Concentrate Drawn
Amount of Concentrate Drawn
Dilution ratio, then, equals X parts water to one part concentrate (X:1). If the test does not yield the desired
ratio, choose a different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper),
and 2) titration. Contact your concentrate supplier for further information on these alternative methods and the
materials required to perform them.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
25
24
23
22